33522129701_0_1 

HX 2700 TB UK 

Summary of Contents for HX 2700 TB UK

Page 1: ...GENERATING SET USER AND MAINTENANCE MANUAL 33522129701_0_1 HX 2700 TB UK ...

Page 2: ...2 4 A A A 3 5 4 7 3 8 1 2 17 12 16 6 9 10 11 13 ...

Page 3: ...3 4 A B C D 15 14 1 2 3 1 2 4 3 2 1 ...

Page 4: ...4 4 E F G 2 1 2 6 4 5 7 3 8 1 ...

Page 5: ... starting the generating set 1 2 3 1 Important refer to the documentation accompanying the generating set 2 Warning emission of toxic exhaust gases Do not use in a confined or poorly ventilated area 3 Stop the motor before filling with fuel A Generating set model B Generating set output C Voltage D Amperage E Current frequency F Power factor Example of an identification plate G Protection rating H...

Page 6: ...trical cables and the connections in good condition Do not use equipment in a poor state of repair which could lead to electrocution or damage to the equipment Use a differential protection device between the generating set and the appliances if the cable or cables used are more than 1 metre in length This device must be positioned at a maximum distance of 1 metre from the generating set electrica...

Page 7: ...park arrester and you need to use it in wooded bushy or uncultivated areas be extremely careful and make sure that sparks do not cause a fire clear vegetation from a fairly large area where you wish to place your generating set 1 3 10 Danger of moving parts Warning Never go near a moving part that is in operation if you have loose clothing or long hair that is not enclosed in a protective hair net...

Page 8: ...rating set earth connection and to an earthing rod of galvanised steel set in the ground to a depth of 1 metre This also dissipates the static electricity that builds up in the electrical machines 3 4 Positioning the generating set for operation Place the generating set on a flat horizontal surface which is firm enough to prevent the set sinking down under no circumstances should the set tilt any ...

Page 9: ...itches Any overload and or short circuits cause the supply of electrical energy to be cut 6 Maintenance schedule 6 1 Reminder of use The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme However it should be added that it is the environment in which the generating set is operating which determines this programme Accordingly if the set is ...

Page 10: ...rm to ensure that drainage is rapid and complete n Remove the filling plug gauge no 1 fig B and the drain plug no 3 fig B and drain the oil into a suitable container o On completion screw up again and tighten the drain plug no 3 fig B p Fill the engine oil sump with the recommended oil then check the level q Put in place and tighten the filling plug gauge no 1 fig B r Check that there is no oil le...

Page 11: ...Drain the carburettor by loosening the drain screw Collect the petrol in a suitable container r Change the engine oil s Remove the spark plug and pour about 15 ml of oil into the cylinder then refit the spark plug t Leave the engine to run for a few moments to distribute the oil in the cylinder u Clean the generating set and cover the engine again to protect it from dust v Store the generating set...

Page 12: ...mm2 16 0 mm2 26 6 0 mm2 16 0 mm2 16 0 mm2 28 6 0 mm2 16 0 mm2 16 0 mm2 12 EC Declaration of conformity Name and address of manufacturer SDMO 12 bis rue de la Villeneuve CS 92848 29228 BREST CEDEX 2 Description of the equipment Product Generating set Make SDMO Type HX 2700 TB UK Electrical output supplied Rated output 2000 W G G Le Gall the manufacturer s authorised representative hereby declares t...