7.6.

 

Checking bolts, nuts and screws 

Daily, detailed checks of all nuts, bolts and screws are essential in order to prevent any accidents or breakdowns.  

n

 

Inspect the generating set as a whole before and after each use.  

o

 

Tighten any loose nuts or screws. 

NB

: the tightening of cylinder head bolts should be carried out by a specialist. Contact your local agent. 

 

7.7.

 

Cleaning the generating set 

n

 

Remove all dust and debris from around the exhaust and clean the generating set using a cloth and a brush (cleaning with a water 
jet is not recommended, and cleaning with high-pressure cleaning equipment is forbidden). 

o

 

Carefully clean the motor air inlets and outlets and the alternator. 

p

 

Check the general condition of the generating set and, if necessary, replace any faulty parts. 

 

8.

 

Storing the generating set 

Generating sets which are to remain unused for a long period of time must undergo certain procedures, in order to keep them in good 
condition. Check that the storage area is not dusty or humid. Clean the exterior of the generating set and apply rustproofing product. 

n

 

Close the fuel tap (

OFF 

position), remove the sediment bowl and drain it. 

o

 

Open the fuel tap (

ON 

position) and drain the petrol from the tank into a suitable container. 

p

 

Refit the sediment bowl and tighten fully.  

q

 

Drain the carburettor by loosening the drain screw. Collect the petrol in a suitable container. 

r

 

Change the engine oil. 

s

 

Remove the spark plug and pour about 15 ml of oil into the cylinder, then refit the spark plug. 

t

 

Leave the engine to run for a few moments to distribute the oil in the cylinder. 

u

 

Clean the generating set and cover the engine again to protect it from dust. 

v

 

Store the generating set in a clean, dry place. 

 

9.

 

Fault finding 

Probable causes 

Remedial action 

The generating set is being charged during start-up 

Take it off charge 

Fuel level too low 

Fill up with fuel 

The fuel tap is closed 

Open the fuel tap 

Fuel supply blocked or leaking 

Have the system repaired 

Blocked air filter 

Clean the air filter 

Control on "

OFF"

 or "

О

Place the control on "

ON"

 or "

I"

 

The engine will not 
start 

Defective spark plug 

Replace the spark plug 

Probable causes 

Remedial action 

Blocked ventilation inlets 

Clean the air inlet and outlet guards 

The engine cuts out 

Probable overcharge 

Check the charge 

Probable causes 

Remedial action 

Circuit-breaker tripped 

Reset the circuit breaker 

Circuit-breaker faulty 

Have it checked, repaired or replaced 

Faulty socket 

Have it checked, repaired or replaced 

Faulty appliance supply lead 

Change the lead 

Faulty alternator 

Have it checked, repaired or replaced 

No electric current 

Switched on the wrong position  

Change the position 

Probable causes 

Remedial action 

Circuit breaker trips 
out 

Faulty equipment or lead 

Have it checked, repaired or replaced 

 

Summary of Contents for HX 2700 TB UK

Page 1: ...GENERATING SET USER AND MAINTENANCE MANUAL 33522129701_0_1 HX 2700 TB UK ...

Page 2: ...2 4 A A A 3 5 4 7 3 8 1 2 17 12 16 6 9 10 11 13 ...

Page 3: ...3 4 A B C D 15 14 1 2 3 1 2 4 3 2 1 ...

Page 4: ...4 4 E F G 2 1 2 6 4 5 7 3 8 1 ...

Page 5: ... starting the generating set 1 2 3 1 Important refer to the documentation accompanying the generating set 2 Warning emission of toxic exhaust gases Do not use in a confined or poorly ventilated area 3 Stop the motor before filling with fuel A Generating set model B Generating set output C Voltage D Amperage E Current frequency F Power factor Example of an identification plate G Protection rating H...

Page 6: ...trical cables and the connections in good condition Do not use equipment in a poor state of repair which could lead to electrocution or damage to the equipment Use a differential protection device between the generating set and the appliances if the cable or cables used are more than 1 metre in length This device must be positioned at a maximum distance of 1 metre from the generating set electrica...

Page 7: ...park arrester and you need to use it in wooded bushy or uncultivated areas be extremely careful and make sure that sparks do not cause a fire clear vegetation from a fairly large area where you wish to place your generating set 1 3 10 Danger of moving parts Warning Never go near a moving part that is in operation if you have loose clothing or long hair that is not enclosed in a protective hair net...

Page 8: ...rating set earth connection and to an earthing rod of galvanised steel set in the ground to a depth of 1 metre This also dissipates the static electricity that builds up in the electrical machines 3 4 Positioning the generating set for operation Place the generating set on a flat horizontal surface which is firm enough to prevent the set sinking down under no circumstances should the set tilt any ...

Page 9: ...itches Any overload and or short circuits cause the supply of electrical energy to be cut 6 Maintenance schedule 6 1 Reminder of use The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme However it should be added that it is the environment in which the generating set is operating which determines this programme Accordingly if the set is ...

Page 10: ...rm to ensure that drainage is rapid and complete n Remove the filling plug gauge no 1 fig B and the drain plug no 3 fig B and drain the oil into a suitable container o On completion screw up again and tighten the drain plug no 3 fig B p Fill the engine oil sump with the recommended oil then check the level q Put in place and tighten the filling plug gauge no 1 fig B r Check that there is no oil le...

Page 11: ...Drain the carburettor by loosening the drain screw Collect the petrol in a suitable container r Change the engine oil s Remove the spark plug and pour about 15 ml of oil into the cylinder then refit the spark plug t Leave the engine to run for a few moments to distribute the oil in the cylinder u Clean the generating set and cover the engine again to protect it from dust v Store the generating set...

Page 12: ...mm2 16 0 mm2 26 6 0 mm2 16 0 mm2 16 0 mm2 28 6 0 mm2 16 0 mm2 16 0 mm2 12 EC Declaration of conformity Name and address of manufacturer SDMO 12 bis rue de la Villeneuve CS 92848 29228 BREST CEDEX 2 Description of the equipment Product Generating set Make SDMO Type HX 2700 TB UK Electrical output supplied Rated output 2000 W G G Le Gall the manufacturer s authorised representative hereby declares t...