1. Technical specifications 

 

 

 

Threshold value of current limit (limiting current), А  

5 … 35 

(adjustable) 

Operating frequency of modulator (adjustable), KHz 

0,25 … 2 

Range of the automatic control of consumed power and gas output, % 

0 … 100 

Possibility of combining modulators 

Present 

Maximum operating temperature of electrolyzer (threshold of protection 
operation), 

о

С  

77 

Option 

Stabilization of the output current 

Present 

Protection against short-circuit in the electrolyzer 

Present (95А) 

Protection against overheating of the modulator 

Present, 120

o

Operating voltage, V 

10 … 28 

Built-in power supply filter 

Present 

Indication of solution density (Indicator “norm”) 

Present 

Adjusting the sensitivity of the detonation sensor 

Present 

 

 

 

 

 

Summary of Contents for M1-03

Page 1: ...Current modulator 1 03 User Manual www sds max com ua...

Page 2: ...Page 1 Technical specifications 3 2 Completeness of set 4 3 Description of the current modulator setting 5 3 1 Connection of the current modulator 6 3 2 Current modulator setting 8 4 Warranty obligat...

Page 3: ...tors Present Maximum operating temperature of electrolyzer threshold of protection operation 77 Option Stabilization of the output current Present Protection against short circuit in the electrolyzer...

Page 4: ...2 Completeness O No Name Quantity Notes 1 Current modulator 1 2 User manual 1 3 Cord set 1 4 Detonation sensor 1 Only for diesel 5 Fuse 1...

Page 5: ...e the heating of the block at fairly high currents Modulator with a current sensor M1 03 is designed so that the limiting current is selected by the tuner and can be in the range of 5 35A The modulato...

Page 6: ...a terminal for fastening with the screw M8 supplied optionally Connection scheme of the modulator is shown in Fig 3 2 Note that the 12V supply or 24V is preferable to take from the terminals of the c...

Page 7: ...ith a current of 25 A the voltage will be 2 9 Volts Installation on the engine with carburetor Connect the blue wire to the terminal K can vary on the ignition coil or the cam of autotrembler If the t...

Page 8: ...el of modulator see Fig 3 6 Figure 3 6 Increasing of the sensitivity of the detonation sensor 3 2 Modulator setting The Modulator is set after electrolyzer system is set filling the system with soluti...

Page 9: ...tor The position of switches is set according to Table 3 1 Fig 3 8 Table 3 1 Compliance with the location of switches and current limitation Current A Location of switches No 1 No 2 No 3 4 35 ON ON ON...

Page 10: ...ordance with the exploitation manual does not follow the recommendations of the manufacturer The device is removed from the warranty in the following cases If the device is opened If there is mechanic...

Reviews: