3.1. Connection of current modulator

 

 

Work on the connection of the modulator  must be carried out with the accumulator 

switched off. 

Before starting the installation, select a location for installation of the modulator. 
The modulator must be installed in a place protected from excessive heat and moisture. It 

is preferably to be nearby the accumulator. 

After fixing the modulator, connect the wire of electrolyzer to its terminal block (see. Fig. 

3.3., 3.4.). 

On  the  electrolyzer  install  the  temperature  sensor,  which  is  designed  as  a  terminal  for 

fastening with the screw M8 (supplied optionally). 

Connection  scheme  of  the  modulator  is  shown  in  Fig.  3.2.  Note that  the  12V  supply  (or 

24V) is preferable to take from the terminals of the car’s electrical generator. 

 
 

Installation on injection engine 

Connect the blue wire from the modulator to the signal wire of fuel nozzle. The black wire 

should be connected from terminal of modulator “Power –” to the car body.  

A  fuse  wire  from  the  terminal  “Power 

”  should  be  connected  to  the  terminal  “+”  of 

electric generator or accumulator (see. Fig. 3.2, 3.3.). 

 
Fig.  3.2.  Connection  scheme  of  the  modulator  to  the  electrolyzer  with  a  single  wire. 

(standard set)  

 

Fig. 3.3. 

Connection scheme of the modulator to the electrolyzer with two wires

 

Summary of Contents for M1-03

Page 1: ...Current modulator 1 03 User Manual www sds max com ua...

Page 2: ...Page 1 Technical specifications 3 2 Completeness of set 4 3 Description of the current modulator setting 5 3 1 Connection of the current modulator 6 3 2 Current modulator setting 8 4 Warranty obligat...

Page 3: ...tors Present Maximum operating temperature of electrolyzer threshold of protection operation 77 Option Stabilization of the output current Present Protection against short circuit in the electrolyzer...

Page 4: ...2 Completeness O No Name Quantity Notes 1 Current modulator 1 2 User manual 1 3 Cord set 1 4 Detonation sensor 1 Only for diesel 5 Fuse 1...

Page 5: ...e the heating of the block at fairly high currents Modulator with a current sensor M1 03 is designed so that the limiting current is selected by the tuner and can be in the range of 5 35A The modulato...

Page 6: ...a terminal for fastening with the screw M8 supplied optionally Connection scheme of the modulator is shown in Fig 3 2 Note that the 12V supply or 24V is preferable to take from the terminals of the c...

Page 7: ...ith a current of 25 A the voltage will be 2 9 Volts Installation on the engine with carburetor Connect the blue wire to the terminal K can vary on the ignition coil or the cam of autotrembler If the t...

Page 8: ...el of modulator see Fig 3 6 Figure 3 6 Increasing of the sensitivity of the detonation sensor 3 2 Modulator setting The Modulator is set after electrolyzer system is set filling the system with soluti...

Page 9: ...tor The position of switches is set according to Table 3 1 Fig 3 8 Table 3 1 Compliance with the location of switches and current limitation Current A Location of switches No 1 No 2 No 3 4 35 ON ON ON...

Page 10: ...ordance with the exploitation manual does not follow the recommendations of the manufacturer The device is removed from the warranty in the following cases If the device is opened If there is mechanic...

Reviews: