Field
Description
Tag
Text that identifies unequivocally the
Static point
within the
Machine
. Only ASCII
alphanumeric characters are allowed, including ”.”, “
-
”, and “_”. Any other special
characters or blank spaces are not allowed. First character must be alphanumeric.
Maximum length is 25 characters.
Enabled
Disabling causes the
Static point
to be omitted on the calculations and ignored by the
Dashboard
. In that case, the values referred to the point will not be calculated and
cannot be referred to in expressions.
Hidden
Hidden causes the
Static point
to be ignored on the
Dashboard
, so that it will not be
displayed on any of its widgets. Unlike with Disabling, the value will still be calculated
and updated each monitoring cycle, so that it can be used for internal calculations
(Machine States, Formula points, etc.)
Name
Text used on the
Dashboard
to identify the
Point
.
Description
Allows the user to include a description of the
Point
.
Technique
Sets the technique associated with the
Point
.
Component
Selects the
Machine
component to be assigned to the
Point
.