Vigilant User Manual
94/232
Storage
These objects define the storage strategies that the unit will apply for the different
measurements of the Machine. They are configured by selecting an event and setting
a condition. For each Machine as many Storage strategies as required can be created.
See Storage Strategies for more information.
Processing
Modes
Processing modes set the signal processing that will be applied to the inputs of the
VIGILANT (filtering, enveloping, rectification, etc.) and defines the properties of the
spectrum and waveform that will be measured on each Point (sampling frequency,
window type, resolution, averages, number of samples, number of bins, etc.). For each
Point, the system can measure several Processing modes, with a maximum of 26
cumulated for all the Points.
Parameters
These are scalar indicators that are calculated from the time signal configured at
the
Processing Mode
and using different mathematical algorithms (overall values,
spectral bands, crest factor, kurtosis, etc.).
The Machines defined on the unit will be displayed on the configuration tree, below the “Machines”
label. Alternatively, clicking on Machines, on the configuration tree, the interface will display the list
of machines.
From this list, the machines can be deleted or copied by using the buttons on the right of each item.
Clicking on one of the machines of the list, or on the tree, the interface will show its configuration.
Click on the
“new” button to create a new machine from scratch.