Vigilant User Manual
200/232
Runout is measured and recorded during slow roll to minimize the unbalance effects of rotation (i.e.
no dynamic shaft movement).
Field
Description
Magnitude
(runout)
Magnitude value to compensate for the runout position of the shaft.
Angle (runout) Angular value to compensate for runout position of the shaft.
Runout reference may be set directly from the display mode using the link available in
the cursor window.
Field
Description
Display
Use (or not) lines to connect the points in between.
Layout
Show Bode, Polar, or both Plots
Horizontal
Lines
Shows or hides horizontal grid lines on the
Widget
.
Vertical
Lines
Shows or hides vertical grid lines on the
Widget
.
13.14.2.
Display
The following picture shows the phase plots
Widget
and its components.