Vigilant User Manual
224/232
15.
Basic Operations
15.1.
Starting Up the Unit
Connect the unit to the power supply as described in Power supply. Once the unit is powered, it will
start up. The
Vigilant
has a start-up period of several seconds. This time can vary from 10 to 15
seconds.
The power led is used to indicate the status of the
Vigilant
during the start-up. During start-up, the
status indicator will be turned on with a solid red color. After the start-up period the indicator turns
into solid green, meaning the device start-up is completed successfully.
In case the power led keeps on red color that means the system presents a problem.
See Troubleshooting.
15.2.
Powering off the unit
Switch off the power supply or remove the power connector to shut down the system.
The
Vigilant
includes a battery that will make the system to shut down properly.
When the
Vigilant
detects a loss in the power supply, it automatically initiates its shutdown. After it is
down if power supply comes back the unit will start up again. In case the power supply comes back
during the shutting down the process will continue until it is down, remaining in this condition for 1
minute. After that period, the unit will start up again.
15.3.
Upgrading the firmware
This option is available in
System
interface, in the Upgrade firmware form:
Moreover, the firmware can also be updated by selecting a file (download from our servers) in your
network location. Otherwise, you will need direct connection to the Internet to execute the upgrade.
The
Vigilant
must have access to the Internet and have necessary Network Ports open.
Online firmware upgrades require the
Vigilant
unit to have direct access
to the Internet. It is therefore recommended to consider this
requirement when defining the project and take actions for an easy way
to connect the system to the Internet. It is also recommended when
support by
Vigilant
is required. Required Network Ports must also be
open.
Otherwise, the firmware can be downloaded at: