5. 

Install an “LE” sensor into any of the (6) or (12) sensor

ports, making sure the sensor is “closed.”  Turn the key to
the LEFT “ON” position. 

Special Note:

The Key Can Only Be Removed In

The “ON” Position.

WHEN THE UNIT IS TURNED ON:

each port that has a

sensor plugged into it will flash for about (5) seconds.  At
the end of (5) seconds, the green light at the top of the
Alarm Module will flash once and remain on if AC power is
available.

The Red Light(s) Flashing for (5) Seconds Indicates:

that the unit has located that sensor and it is “working cor-
rectly.” In the Battery Mode the Green Light that Flashes
every (5) Seconds Indicates: that the unit is constantly
checking the condition of the batteries, and they are in
GOOD condition.

Low Battery Indication:

The GREEN indicator light will

continually flash along with a “BEEP” from the horn.

8. 

Remove the backing sheet from an  adhesive and apply

it to the bottom of the sensor.  

PRESS

it 

FIRMLY into

place

to form a good bond.

9.

Remove the second backing sheet,

and apply the sensor to the merchan-
dise on the area cleaned for the sen-
sor. 

PRESS

it

FIRMLY into place

to

form a good bond.

10. 

Plug the sensor into one of the (6) or (12) sensor ports

of the Mini T-Series Alarm Module.  Continue applying
sensors to merchandise, and plugging them into the Alarm
Module, you may use all of the ports to secure items.

11. 

Turn the key to the LEFT “ON” position.  The Mini T

Alarm Module will now independently scan the (6) or (12)
sensor ports for tampering.  The unit also continually
checks the AC and battery powered condition with a

GREEN light

to show it is operating. 

Tampering

is the removal of Sensors from the Alarm

Module, from Merchandise, Inserting Metal Objects into
Open Sensor Ports, or the attempt to short out a Sensor. 

12. To Add or Remove Sensors:

Insert the key into the

lock and turn it to the RIGHT “Stand-By” position.  While
the unit is in the “Stand-By” mode, it will 

“BEEP”

once

every (30) seconds to warn employees to turn the unit
back on.

13

. To Re-Set the unit after an Alarm:  Insert the key into

the lock and turn it to the RIGHT “Stand-By” position. 

NOTE:

During the “Alarm Mode” and after the key has

been turned to the “Stand-By” position, the 

RED indicator

lights 

will continue to flash, indicating which sensor caused

the alarm.  Correct the problem/sensor that caused the
alarm and turn the key back to the LEFT “ON” position.
The system will always search through its ports and check
battery condition when turned to the “ON” position.

6. 

Turn the Mini T Alarm

Module Key to the “Stand-
By” position.  This is the
position that you cannot
remove the key.

7.

Connect an LE sensor

to the merchandise that is
to be protected, follow the
important cleaning step closely. 

VERY IMPORTANT!

Clean the area on the product

and the bottom of the sensor with Alcohol Prep
Pads.  While the alcohol is still wet, 

Wipe These

Surfaces DRY

with a clean paper towel.  If the

paper towel shows dirt, 

REPEAT THE CLEANING

STEP until the surfaces are Clean & Dry!

Alarm Module Testing:

Operating Instructions:

Rectangular
Adhesive Pads

Remove adhesive backing

P/N: 64683      SCI-9984