M
EM
B
R
AN
E
INS
T
ALLA
TIO
N
The Membrane should be installed horizontally within a reasonable
distance of the Control Panel and the High Pressure Pump. When
selecting a location for the Membrane, be sure to account for the
additional space required for hose
fi
ttings.
►►►
The Membrane should not be near sources of heat,
such as the generator or refrigeration.
The Membrane requires 2 mounting brackets. These brackets should be padded with rubber and should
be
fi
rmly, but not too tightly, clamped around the high pressure vessel.
SE
A
W
A
TER
LIFT
PU
MP
INS
T
ALLA
TIO
N
The Seawater Lift Pump may be installed on a bulkhead with the
bracket that was included with your watermaker or it may be threaded
directly onto the through-hull
fi
tting. If you are mounting it on a
bulkhead, the pump must be installed a minimum of 2” below the
waterline, as close to the through-hull as possible.
❶
Once the pump has been mounted, run the brown wire to the wiring
harness on the panel and run the black wire to the [-] buss.
❷
Run a 3/4” hose from the output of the Seawater Lift Pump to the
hose barb on the panel labeled “Seawater Intake.” Secure using
stainless steel hose clamps.
Sea Clear Watermakers™ Manual - Version 1.1-G
Page 29
The membrane is shipped with plugs in the end caps where the hose
fi
ttings will be installed.
Do not remove these plugs until you are prepared to install the hose. If the plugs are removed
and the membrane is allowed to dry out, you will need to purchase a replacement membrane.
Brine
Product
Input