P
RE
-
FI
L
TER
S
►►►
Use only 5-micron 10” polyester
fi
lter elements, such as Katadyne 8012861. These can be found
at most marine and water supply stores.
Pre-
fi
lters should be replaced regularly. To determine the status of your Pre-
fi
lter element, use the Pre-
fi
lter Pressure Gauge on the Control Panel. This gauge should stay at or above zero PSI when the system
is in operation. If the gauge shows a negative pressure or a vacuum, it’s time to replace the element.
Replacement Procedure
❶
Shut down the system and ensure that the Sea Water Lift Pump is OFF and through-hull is closed.
❷
Unscrew the Pre-
fi
lter Housing and remove the Pre-
fi
lter element.
❸
Discard the used element and install a new 5-micron polyester element.
❹
Reassemble by securely screwing the Pre-
fi
lter Housing back together.
❺
When restarting the system, be sure to check the Pre-
fi
lter Housing for leaks.
H
IGH
P
RE
SSU
RE
PU
MP
Your watermaker system includes an AR North America High Pressure Pump. Designed for long life, the
pump should provide years of trouble-free operation if maintained and inspected regularly.
During installation, the gear case was
fi
lled with 9.81 oz. ISO 100 - NA 30 weight hydraulic oil and the
bolts and belts were adjusted. It is good practice to inspect the belt and check the gear case oil every 20
hours of operation.
See the following pages for information regarding the electric motor.
Sea Clear Watermakers™ Manual - Version 1.1-G