H
IGH
P
RE
SSU
RE
PU
MP
INS
T
ALLA
TIO
N
High Pressure Pump RPM
Minimum
Maximum
Recommended
1250
1800
1725
*Decreasing the RPM of the pump will simply decrease the production of fresh water.
To determine your generator’s operating RPM, refer to the AR North America chart below.
►►►
Go back to page 6 and write your generator’s RPM in the gold-colored box for future reference..
Sea Clear Watermakers™ Manual - Version 1.1-G
Page 27
B
racket Requirements
Before installing the high pressure pump, you’ll need a bracket to mount it to the generator.
• The pump must be mounted as level as possible with the oil dipstick on top of the unit.
• The pump can be turned in either direction.
• The bracket should be made of mild steel and painted prior to installation.
• The bracket should include a method for tensioning the belt.
►►►
It is recommended that a quali
fi
ed metal fabricator or mechanic build and install the
bracket.