❻
Turn on Seawater
Lift Pump
❼
Turn on High
Pressure Pump
and let system
run for 1 minute
to purge air
❽
Slowly turn
Pressure
Adjustment
Needle Valve
clockwise,
increasing
to operating
pressure of 800
psi
❶
Start generator, bringing it up to operating
temperature and steady RPM
❷
Turn Seawater
valve to
“Seawater intake”
position
❸
Turn Fresh Water
valve to “Flush
tank” position
❹
Place hose labeled “To
fl
ush tank” into 5
gallon bucket
❺
Turn Pressure
Adjustment
Needle Valve
counterclockwise
2 times
Sea Clear Watermakers™ Manual - Version 1.1-G
Page 8
QU
ICK
GU
IDE
T
O
O
PER
A
TIO
N