Before operating the protected vessel, visually inspect pressure gauge for compliance and
ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica-
tor light is extinguished, remove, and replace the system immediately.
Never paint or obstruct the detection tube, as this will adversely affect its operating charac-
teristic. FT models are non-refillable. See nameplate on cylinder for instructions and OUT
OF WARRANTY REPLACEMENTS section of this manual.
REMINDER:
• FREQUENTLY CHECK GAUGE FOR PROPER PRESSURE
LIMITATIONS
Sea-Fire FT model series FM-200
®
automatic fire extinguishers are designed and tested to
extinguish Class C (electrical) and Class B (flammable liquid) fires in enclosed compart-
ments only. Any open doors or hatches will allow discharging agent to escape and will seri-
ously affect the ability of the agent to extinguish the fire.
Only one extinguisher may be used to protect a compartment. If more than one extinguisher
is used to achieve the required amount of agent concentration, there is no guarantee that
several extinguishers will actuate simultaneously as each extinguisher operates indepen-
dently. Several extinguishers may be used only if each independent extinguisher is capable
of protecting the entire volume of the compartment.
OPTIONAL EQUIPMENT
SDDA I
Panel mounted visual/audible discharge alarm unit.
ESRS-2
Panel mounted system status indicator with override switch for engine(s)
restart. For use with the ESRS engine shutdown system as a replace-
ment or add-on second helm station.
ESRS III, V, VIII
Engine and powered ventilation (blower) shutdown system. Includes
one circuit control unit and one panel mounted ESRS-2 visual/audible
system status indicator with override switch for engine restart. Avail-
able with 3,5, or 8 control circuits in 12 or 24 VDC models.
ESRS-WT III, V, VIII Same as ESRS-MARK shutdown system, but also includes a factory-
installed nominal 20-second release timer on the engines control cir-
cuits. For use in diesel engines that shutdown through activation of a
momentary device (i.e., push button, lever, etc.).
SFAB12 (24)
Discharge alarm bell 6" round 12 or 24 VDC models.
ESEH-10
10 foot (3.05 meter) extender harness for use with ESRS systems.
ESEH-30
30 foot (9.15 meter) extender harness for use with ESRS systems.
Contact Sea-Fire or an authorized Sea-Fire dealer for details.
THREE (3) YEAR FT SERIES LIMITED WARRANTY
We warranty to the original retail purchaser all SEA-FIRE extinguishers for a period of three
(3) years after retail purchase against defective material and faulty workmanship, any sys-
tem found to be defective during the warranty period will be repaired if possible, or replaced
free of charge if classified non-refillable (according to product label) upon the prepaid return
of the defective system. Proof of purchase required, otherwise date of manufacturer on extin-
guisher label will apply. This warranty gives you specific legal rights which may vary by state
or country.
THE FOREGOING WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES WITH
RESPECT TO THE SYSTEM INCLUDING ANY IMPLIED WARRANTY OF MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO PERSON IS AUTHORIZED
TO GIVE ANY OTHER WARRANTY, OR TO ASSUME FOR SEA-FIRE MARINE ANY OTHER
LIABILITY IN CONNECTION WITH THE SALE OR INSTALLATION OF ITS PRODUCTS.
REPLACEMENT OF THE SYSTEM WILL BE THE SOLE REMEDY WITH RESPECT TO
ANY LOSS OR DAMAGE TO PROPERTY. BUYER IS NOT RELYING ON SELLER’S JUDG-
MENT REGARDING BUYER’S PARTICULAR REQUIREMENTS AND BUYER HAS HAD
AN OPPORTUNITY TO INSPECT THE PRODUCT TO BUYER’S SATISFACTION.