(335 Sundancer
®
)
dry place. Do not store on concrete.
•
Keep under a trickle charge.
•
When placing battery back into service, remove
excess grease from terminals, recharge as
necessary and reinstall in boat.
D. H
EAD
S
YSTEM
•
Flush entire system thoroughly with fresh water.
•
Pump out holding tank.
•
Remove water line from inlet fitting located
on back bottom half of water valve on head.
•
Flush one gallon (four liters) antifreeze mixed
with one gallon (four liters) of water through toilet
and let vacuum pump run for one or two
minutes.
•
Shut WATER SYSTEM breaker OFF.
•
Pump out holding tank.
E. W
ATER
S
YSTEM
•
Turn ON the WATER SYSTEM switch.
•
Open water faucet, let system drain completely.
•
Turn OFF the WATER SYSTEM switch.
•
Water must be removed from the water lines
with air pressure or flushed with a nontoxic
antifreeze.
Using pressurized air to remove water from water
lines:
•
You must have an air compressor with air hose
and air nozzle.
•
Remove water hoses from water pump.
•
Alternate opening one faucet at a time to make
sure water is removed from each line.
•
Blow air through the water lines removed from
the water pump.
NOTE:
When blowing air be careful not to blow air
with all faucets closed. System could be damaged
by overpressurization and create water leaks.
•
Cover hose ends with screen or broad weave
cloth and tape in place to keep out dirt and bugs.
U
SING
NONTOXIC
WINTERIZING
ANTIFREEZE
:
•
Purchase a nontoxic winterizing antifreeze for
fresh water systems from a marine or RV supply
retailer.
•
With all water pumped out of the system add
nontoxic antifreeze to the water tank. Pour in
enough to be pumped to all faucets and
showers.
•
Close all faucets and turn on water system.
•
Open one faucet at a time. Close faucet when
nontoxic antifreeze comes out of faucet.
•
After all faucets and showers have been treated,
open all faucets and pump out remaining
nontoxic antifreeze.
W
ATER
H
EATER
W
INTERIZATION
•
Refer to your water heater Owner’s Manual for
detailed information on preparing water heater
for storage and winterization.
F. F
UEL
S
YSTEMS
G
ASOLINE
:
•
Fill fuel tank with gasoline and the
recommended amount of stabilizer and
conditioner such as “Stabil
®
”.
•
Run engine(s) for ten minutes to ensure that all
gasoline in the carburetor and fuel lines are
treated.
Summary of Contents for 300 Sundancer
Page 2: ......
Page 4: ...ii 300 Sundancer 335 Sundancer...
Page 30: ...This page intentionally left blank...
Page 54: ...3 10 SECTION 3 USING YOUR BOAT 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Page 154: ...9 4 SECTION 9 CARE REFINISHING 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...