8.14
S
ECTION
8 • R
EQUIRED
I
NSPECTION
, S
ERVICE
AND
M
AINTENANCE
300 Sundancer
®
(335 Sundancer
®
)
Q
UICK
R
EFERENCE
C
HECKLIST
(
CONT
’
D
)
Do not run the generator or engines in an
enclosed area, such as a closed boat house, as
there is the possibility of buildup and inhaling of
carbon monoxide.
!
WARNING
G. O
PERATING
THE
G
ENERATOR
S
TARTING
THE
G
ENERATOR
1. Generator Seacock ....................................................... Open
2. Bilge Blowers ................................................................ Run for at least 4 minutes and any time the generator is running
3. Depress PREHEAT (Diesel Only) ................................ Preheat time should not exceed 30 seconds
4. Depress START Switch ................................................ Depress until generator starts
5. When the Generator Starts ........................................... Release the START switch only (If diesel, continue holding
PRE-HEAT for a few seconds)
6. Load The Generator ..................................................... Turn ON the generator main breaker on the Main
Distribution Panel. Turn AC breakers ON
S
TOPPING
THE
G
ENERATOR
1. Breakers ........................................................................ Turn AC breakers OFF. Turn OFF the generator main breaker
on the Main Distribution Panel
2. Generator ...................................................................... Let it run a few minutes to cool down
3. STOP Switch ................................................................. Depress to stop the generator set