7.1
S
ECTION
7 • A
CCESSORIES
AND
O
PTIONS
390 Sundancer
®
(
425 Sundancer
®
)
1. L
AYOUT
AND
A
CCESSORIES
Figures 7.18.1 and 7.19.1 identify the location and
arrangement of the equipment and components on
your yacht. We strongly suggest that you walk
through your yacht, locate the features illustrated,
and become familiar with their operation and
maintenance.
2. C
ARBON
M
ONOXIDE
M
ONITORS
The 390 DA is equipped with a carbon monoxide
(CO) monitors throughout the boat ( See Section
2, General Boat Arrangement, pages 2.24 & 2.25
for location of CO Monitor). The CO monitor is an
electronic instrument that detects carbon
monoxide. When there is a buildup of CO in any
room, the monitor in that room will alert the
occupants by a flashing a DANGER light and
sounding an alarm.
It is important that you read and understand
the CO monitor information and operating
Actuation of the CO monitor indicates the presence of
carbon monoxide which can be FATAL.
EVACUATE THE PREMISES IMMEDIATELY. DO A HEAD
COUNT TO CHECK THAT ALL PERSONS ARE
ACCOUNTED FOR. CALL THE NEAREST FIRE
DEPARTMENT AND ASK THEM TO DETERMINE THE
SOURCE OF CARBON MONOXIDE. DO NOT REENTER
PREMISES UNTIL IT HAS BEEN AIRED OUT AND THE
PROBLEM IS CORRECTED.
!
DANGER
This detector will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide may
be present in other areas.
!
CAUTION
To reduce the risk of carbon monoxide poisoning, test
the monitor operation when not in use for 10 days or
more.
!
CAUTION
C
ARBON
M
ONOXIDE
M
ONITOR
(F
IG
. 7.1.1)
instructions. It is extremely important that you
become familiar with the CO monitor and its
functions.
A. T
ESTING
THE
CO M
ONITOR
Test the monitors on your boat for at manufacturers
required intervals by pushing the TEST button on
the side of the unit. If the unit is operating correctly
both audible and visual warning indicators will be
activated.
REFER TO THE MANUFACTURER’S INSTRUCTION
MANUAL IN THE OWNER’S Manual PACKET FOR
INSTRUCTIONS AND WARRANTY INFORMATION.
3. A
IR
C
ONDITIONING
& H
EATING
The 390 DA air conditioning/heating system
consists of two (2) standard air conditioning/heating
units, a raw water pump with seacock and strainer
and a relay unit so the water pump will be activated
by demand when any AC unit comes on.
Care should be taken so as not to stow items around
the air handlers that may block the return air grill or
damage the freon lines running to the compressor.
The air filters for each unit should be removed and
cleaned periodically to assure fresh, clean air
circulation and to reduce stress on the unit.
The master stateroom unit is a 7,000 BTU unit
located under the bunk. The controls for the unit are
POWER INDICATOR
DANGER INDICATOR
HORN
TEST BUTTON (ON SIDE)
MONITOR LOCATIONS
A
B
C
D
A
B
C
D
*
*
*
*
Summary of Contents for 390 Sundancer
Page 2: ...390 Sundancer 425 Sundancer ii THIS PAGE LEFT INTENTIONALLY BLANK...
Page 12: ...390 Sundancer 425 Sundancer xii THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 30: ...390 Sundancer 425 Sundancer 1 18 SECTION 1 SAFETY THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 34: ...390 Sundancer 425 Sundancer 1 22 SECTION 1 SAFETY THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 102: ...390 Sundancer 425 Sundancer 5 6 SECTION 5 FUEL SYSTEM THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 184: ...390 Sundancer 425 Sundancer Index 4 INDEX THIS PAGE LEFT INTENTIONALLY BLANK...