Aqua Whisper DX Modular 450-1800
Page 7-4
Opera
tion
10. Check for:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Abnormal noises or other occurrences.
11. If any abnormality develops, touch the STOP
button on the Touch Screen. A warning screen will
display.
a) Correct the problem then repeat Step 1-10.
12. Proceed to Log System Readings.
7.1.5 LOG SYSTEM READINGS
1.
Record the System initial performance readings.
Use the New System Initial Readings form on Page
6-8.
2.
Proceed to Shutdown.
7.1.6 SHUTDOWN THE SYSTEM
A. SEMI-AUTOMATIC MODE
1.
Rotate the Back Pressure Regulator counter-
clockwise to decrease operating pressure to
0 psi (0 bar).
2.
From the default screen, touch the STOP button.
a) The 3-Way Product Water Diversion Valve will
revert to unpotable water.
b) The UV Sterilizer will stop.
c) The High Pressure Pump will stop.
d) The Booster Pump will stop.
e) If the System does not include the Automatic
Fresh Water Flush option, the Stop sequence
is complete, or
f) If the System includes the Automatic Fresh
Water Flush option, the Automatic Fresh Water
Flush Valve will energize and after 7 to 15
minutes the Fresh Water Flush Valve will de-
energize and the Stop sequence is complete.
The System will go to a Fresh Water Flush
Stand-by mode until the next automatic Fresh
Water Flush Cycle. The Fresh Water Flush
Cycle will automatically initiate every preset
number of days until canceled or power is
disconnected from the System.
1.
Verify the back pressure regulator valve knob is in
fully open position.
2.
From the default screen, touch the SETUP tab.
3.
On the next screen, touch the Acceptable Salinity
Level button.
4.
On the Salinity Level screen, adjust to desired level
(200 to 1000 PPM) then touch the SETUP button.
5.
On the next screen, touch the Manual Mode button.
6.
On the next screen, touch the Booster Pump
START button then wait 5 seconds for booster
pump to stabilize.
7.
Touch the HP Pump START button.
8.
Slowly increase operating pressure by adjusting
the back pressure regulator valve knob in a
clockwise direction until the product water flow
reaches the System production rate.
a) If the high pressure exceeds 975 psi (67
bar), an alarm will sound and shut down the
System. Manually adjust the back pressure
regulator to 0 psi (0 bar).
b) When production rate is reached, the System
will start monitoring the product water salinity.
Although the system is producing “Product
Water”, the Product Water may not be
“Potable” for up to 30 minutes. The salinity of
the Product Water diminishes gradually, until
it reaches the acceptable level or lower.
PRODUCT SALINITY (RED) simply means that the
dissolved solids in the Product Water have not yet
decreased to acceptable level.
PRODUCT SALINITY (GREEN) simply means that
the dissolved solids in the Product Water have
reached the acceptable level and the Diversion
Valve can be activated.
9.
Activate the Diversion valve when Salinity meter
turns Green.
a). If the tank is not full and the salinity of the
product water drops below the preset salinity
level, the U.V. sterilizer will energize if installed.
b) Feed Pressure, Feed Flow, Operating Pressure,
Brine Flow, Product Flow, and Product Salinity
will be monitored and the System Control
Logic will perform various tasks to maintain
proper functioning of the System.
c). When the tank is full, the System will stop all
operations.
Summary of Contents for Aqua Whisper DX 1400-2
Page 2: ......
Page 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Page 4: ......
Page 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Page 12: ...Introduction...
Page 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Page 16: ...Description...
Page 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Page 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Page 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Page 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Page 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Page 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Page 40: ...Pre installation...
Page 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Page 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Page 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Page 66: ...Electrical...
Page 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Page 80: ...Electrical...
Page 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Page 82: ...Installation...
Page 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Page 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Page 96: ...Commissioning...
Page 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Page 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Page 108: ...Operation...
Page 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Page 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Page 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Page 124: ...Maintenance...
Page 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Page 146: ...Troubelshooting...
Page 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Page 168: ...Parts View...
Page 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Page 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Page 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Page 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Page 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Page 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Page 225: ......