Aqua Whisper DX Modular 450-1800
Page 8-15
Maintenance
A) Do not assume that the Valve’s Solenoid is not
operational. Check it by performing a Function
Test as described in Section 6.4.
B) Over tightening of the tube fittings into the
valve’s body can cause the Diversion Valve
internal ports to move out of proper position
resulting in internal blockage or bypassing.
Refer to Figure 8e through 8f, page 8-15 and
follow the instructions listed below.
1) Remove Diversion Valve from the system.
2) Position the manual over ride button
OUTWARD to normal position by first
pushing the button inward and rotating
it counter clockwise allowing it to spring
outward away from the coil body.
3) With your mouth, blow into port “P”, air
should expel from port “B” which is the
“normally open” or “bad water” port.
4) If it is extremely difficult to expel air from
port “B” or if no air expels from port “B”,
then valve needs to be replaced.
5) Again blow into port “P” while plugging
port “B” with a finger tip. No air should
expel from port “A”.
6) If air expels from port “A”, then valve
need to be replaced.
7) Position the manual over ride button
INWARD to manual over ride position by
pushing the button inward and rotating it
clockwise allowing it to lock inward close
to the coil body.
8) With your mouth, blow into port “P”, air
should expel from port “A” which is the
“normally closed” or “good water” port.
9) If it is extremely difficult to expel air from
port “A” or if no air expels from port “A”,
then valve need to be replaced.
10) Again blow into port “P” while plugging
port “A” with a fingertip. No air should
expel from port “B”.
11) If air expels from port “B”, then valve
need to be replaced.
C) Solenoid Valve Coil Check:
1) The 3-way Product Diversion Valve
Solenoid operates from 12 VDC.
To check the condition of the Diversion
Valve solenoid coil:
a) While System is operating and producing
potable water, using a voltmeter set to DC,
check the voltage at the din connector
terminals at the top of the 3-Way Diversion
Valve’s solenoid.
b) If 12 VDC is present at the din connector
terminals then the control circuit is operating
normally, but the 3-way Diversion Valve Coil
Figure 8e.: VALVE WITH PORT DESIGNATION “A” “P” “B”
PLUG
REMOVE BY LOSENING SCREW
AT TOP AND “POPPING OFF”
OF VALVE BODY
1
VALVE WITH PORT
DESIGNATION
“A” “P” “B”
OUTLET
GOOD / POTABLE
PRODUCT WATER
OUTLET
BAD / NOT POTABLE TO
PRODUCT WATER REJECT
INLET
MANUAL OVER RIDE BUTTON -
PUSH AND TURN CLOCKWISE TO
LOCK VALVE IN THE EMERGENCY
“ON” (SAFE WATER) POSITION
FOR NORMAL POSITION - PUSH
BUTTON AND TURN COUNTER
CLOCKWISE TO RELEASE BUTTON
OUTWARD, AWAY FROM SALENOID.
PLUMBING CONNECTIONS
“A” = NORMALLY CLOSED - TO CHARCOAL FILTER INLET (GOOD WATER)
“P” = INLET (COMMON)
“B” = NORMALLY OPEN - TO DISCHARGE (BAD WATER)
Figure 8f.: VALVE WITH PORT DESIGNATION “R” “B” “P”
REMOVE BY LOSENING SCREW
AT TOP AND “POPPING OFF”
OF VALVE BODY
VALVE WITH PORT
DESIGNATION
“R” “B” “P”
OUTLET
GOOD / POTABLE
PRODUCT WATER
1
OUTLET
BAD / NOT POTABLE TO
PRODUCT WATER REJECT
INLET
MANUAL OVER RIDE BUTTON -
PUSH AND TURN CLOCKWISE TO
LOCK VALVE IN THE EMERGENCY
“ON” (SAFE WATER) POSITION
FOR NORMAL POSITION - PUSH
BUTTON AND TURN COUNTER
CLOCKWISE TO RELEASE BUTTON
OUTWARD, AWAY FROM SALENOID.
PLUG
PLUMBING CONNECTIONS
“R” = NORMALLY CLOSED - TO CHARCOAL FILTER INLET (GOOD WATER)
“B” = INLET (COMMON)
“P” = NORMALLY OPEN - TO DISCHARGE (BAD WATER)
Measure the DC resistance between pins 1 and 2.
Proper resistance reading is aprox. 12 to 15 Ω
Summary of Contents for Aqua Whisper DX 1400-2
Page 2: ......
Page 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Page 4: ......
Page 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Page 12: ...Introduction...
Page 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Page 16: ...Description...
Page 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Page 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Page 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Page 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Page 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Page 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Page 40: ...Pre installation...
Page 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Page 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Page 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Page 66: ...Electrical...
Page 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Page 80: ...Electrical...
Page 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Page 82: ...Installation...
Page 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Page 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Page 96: ...Commissioning...
Page 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Page 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Page 108: ...Operation...
Page 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Page 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Page 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Page 124: ...Maintenance...
Page 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Page 146: ...Troubelshooting...
Page 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Page 168: ...Parts View...
Page 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Page 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Page 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Page 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Page 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Page 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Page 225: ......