background image

Aqua Whisper DX Modular 450-1800

 

Page 9-11

Troubelshooting

 

Solution

: Replace the O-Ring if wear or damage  

is present.

 

Should the End Plug develop a crack, between the 
product water port and the pressurized feed water, 
similar increase in Product Water flow and high 
Product Water salinity will occur.

 

Solution

: Replace the End Plug if it is damaged  

or cracked.

 

At ONE end only of the R.O. membrane element 
there is a “U” cup seal referred to as the “brine 
seal”. NEVER use two Brine Seals. NEVER place 
a Brine Seal on both ends of the R.O. membrane 
element. This will cause an air pocket between 
the outer surface of the R.O. membrane element 
and the inner wall of the Pressure Vessel. The air 
pocket would allow the R.O. membrane element 
to expand outward during operation causing 
irreversible mechanical damage to the R.O. 
membrane element resulting in higher than  
normal Product Water Flow and High Product 
Water Salinity.

 

Solution

: Replace the R.O. membrane element. 

NEVER place two Brine Seals on one R.O. 
membrane element.  

 

NEVER Block the Product Water Line. NEVER place 
a valve in the Product Water Line that can close 
and block the Product Water Line. Blockage of the 
Product Water line will result in high pressure build 
up of 950 PSI (66 BAR) within the line and within 
the product water tube and product water channel 
of the R.O. membrane element. If the System 
is shut down while the Product Water Line is 
blocked irreversible damage to the R.O. Membrane 
element will occur.

 

Solution

: Determine what blocked the Product 

Water Line and correct the condition. Replace the 
R.O. membrane element.

 

Chemical attack, one that will dissolve the 
membrane surface such as an oxidant like 
Chlorine, has destroyed the R.O. membrane 
element surface.

 

Solution

: Determine the source and  

correct the situation. Replace the R.O. membrane 
element.

c) 

Product Water Flow slowly, over months, 
decreases and Product Water Salinity, slowly over 
months, increases, quality decreases:

repairable. Should a leak, damage, or failure develop 
replace the High Pressure Hose.

Solutions

:  Replace a damaged High Pressure Hose

22)   REVERSE OSMOSIS MEMBRANE AND 

VESSEL ASSEMBLY

The Reverse Osmosis Membrane Element allows potable 
water molecules to pass through while rejecting the 
salt ions. Only a small percentage of the Seawater Feed 
becomes fresh Product Water. The remainder carries the 
rejected salt ions out of the R.O. membrane element in 
a concentrated brine stream. The R.O. System may have 
one or two R.O. membrane elements and Vessel in series 
depending on the specific model and system capacity.
Problems and Symptoms appearing and caused by the 
Reverse Osmosis Membrane and Vessel Assembly:
a) 

Prior to assuming that there is a problem  
with the R.O. membrane elements due to your 
observance that:

 

The System does not produce the correct amount 
of Product Water (too much or too little)

 

The System produces poor quality Product Water, 
high in Salinity

 

The System Operating Pressure is excessively 
higher than 800 PSI (55 BAR) when operating in 
normal Sea Water at moderate temperatures (77º 
F or 25º Celsius)

 

The System Operating Pressure is excessively 
lower than 800 PSI (55 BAR) when operating in 
normal Sea Water at moderate temperatures (77º 
F or 25º Celsius)

 

Go to Section 6 to ensure that the Model Set-Up 
has been properly performed.

b) 

Product Water Flow suddenly and dramatically 
increases and Product Water Salinity increases 
making the Product Water unpotable:

 

The Pressurized Feed Water and the unpressurized 
Product Water are separated by an O-Ring which 
seals on the Product Water Tube at each end of the 
R.O. Membrane element and the End Plug at each 
end of the Pressure Vessel. Should this O-Ring 
fail Feed Water will mix with Product Water. If this 
happens the Product Water will be very salty, the 
Product Water Flow will increase dramatically, and 
the Brine Flow will decrease appropriately (by the 
increase in Product Water).

Summary of Contents for Aqua Whisper DX 1400-2

Page 1: ...l Release 1 December 2008 Manual PN B651930002 Revision 10 21 10 SRC Aqua Whisper DX 450 1 SRC Aqua Whisper DX 700 1 SRC Aqua Whisper DX 900 1 SRC Aqua Whisper DX 900 2 SRC Aqua Whisper DX 1400 2 SRC...

Page 2: ......

Page 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...

Page 4: ......

Page 5: ...from improper installation and from improper operation The use of third party non Sea Recovery consumable spares and assemblies will damage the Sea Recovery system and or specific components within t...

Page 6: ...performance of the content within this manual is strictly prohibited TERMS AND CONDITIONS The use of this manual acknowledges acceptance of the terms and conditions provided herewith and the agreement...

Page 7: ...ages Description 1 December 2008 Initial Release of 2008 DX Models 1 23 September 2008 4 11 and Foldouts Revised Electrical Diagrams 2 08 December 09 page 5 2 General Reformatting and Multi Media filt...

Page 8: ...ON NOTES 3 1 3 1 PRECAUTIONS 3 1 3 2 SPECIAL CONSIDERATIONS 3 1 3 3 DISTANCE BETWEEN COMPONENTS 3 2 3 5 COMPONENTS SUPPLIED BY INSTALLER 3 2 3 6 PIPING AND INTERCONNECT DIAGRAMS 3 3 3 7 EXPLANATION OF...

Page 9: ...NGS 6 7 6 6 5 SHUTDOWN THE SYSTEM 6 7 6 7 WARNINGS AND CAUTIONS 6 7 7 OPERATION 7 1 7 1 DAILY OPERATION 7 2 7 1 1 POSITION VALVES 7 2 7 1 2 APPLY POWER TO THE SYSTEM 7 2 7 1 3 START THE SYSTEM 7 3 7 1...

Page 10: ...PUMP ASSY 3 PHASE 60Hz B156930004 Standard 10 21 15 HP PUMP ASSY 12180513CO RIGHT 10 22 16 HP PUMP ASSY SINGLE PHASE B1561400O1 Optional 10 24 17 HP PUMP ASSY 3 PHASE B156140002 Optional 10 25 18 HP H...

Page 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...

Page 12: ...Introduction...

Page 13: ...mbrane element BRINE VELOCITY The brine flow over the membrane surface is very important to both product water quality and quantity At low flows concentration polarization occurs causing the water qua...

Page 14: ...TION Some densification of the membrane structure may take place while operating at elevated pressures above 1000 PSI The change is known as compaction and is accompanied by a reduction in the water p...

Page 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...

Page 16: ...Description...

Page 17: ...an CE Conformit Europ ne Refer to Page 2 5 for compliance certificates 2 4 WARRANTY Sea Recovery guarantees its product components and replacement parts and recommends customers to use only Sea Recove...

Page 18: ...electronic monitoring The salinity monitoring components of the system give a continuous readout in micro ohms per cubic centimeter are temperature compensated and of a fail safe design SALINITY RANG...

Page 19: ...bs 73 kg Aqua Whisper 1400 2 167 lbs 76 kg Aqua Whisper 1800 2 172 lbs 78 kg ELECTRICAL MOTOR SPECIFICATIONS H P Horse Power RPM Revolutions Per Minute FLA Full Load Amperes LRA Locked Rotor Amperes S...

Page 20: ...TO AQUA WHISPER BOOSTER PUMP Operating Phase Maximum Recommended Minimum Wire Size for Length of run Voltage Load 10 Ft 3 meter 25 Ft 8 meter 50 Ft 15 meter 110 115 VAC Single 9 4 Ampere 14 AWG 2 5 m...

Page 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...

Page 22: ...dards is recorded in the issue of a Product Design Assessment PDA certificate The process is the same as would be followed for an ABS Design Review Letter It imitates the Module B category of the MED...

Page 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...

Page 24: ...C Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate...

Page 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...

Page 26: ...he applicable directives This mark allows manufacturers and exporters to circulate products freely within the 15 European Union EU members Having ensured that the equipment does indeed meet all these...

Page 27: ...petroleum products attack extreme temperatures over 120 F 49 C under 32 F 0 C drying out or extreme pressures over 1000 psig 69 bar In the event of a defect a malfunction or failure specifically cove...

Page 28: ...x loss loss of production of the R O membrane element s This damage is irreversible to the R O membrane element and not covered by warranty e Freezing temperatures will cause mechanical damage to the...

Page 29: ...CH 12 B645800002 MCC 2 ACID CLEANER 1 00 EACH 13 0328066666 HOSE CLEAR BRAID 3 4 50 00 FEET 14 0101013783 ELB90 3 4 FPT X 3 4 FPT PVC 1 00 EACH 15 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC 3 00 EACH 16 0...

Page 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...

Page 31: ...per DX Modular 450 1800 Page 2 15 Description MODULAR UNIT DIMENSIONS Radial Axial Pump 19 483 mm 11 279 mm 7 178 mm 9 229 mm 10 254 mm 6 75 17 38 18 75 20 25 11 38 Note Illustration shows the optiona...

Page 32: ...DX Modular 450 1800 Page 2 16 Description COMPONENT DIMENSIONS Sea Strainer Dual Pre filter Dual Post filter Booster Pump a 46 15 16 1192mm 900 1 1800 2 b 37 15 16 964mm 700 1 1400 2 c 27 15 16 710mm...

Page 33: ..._____________________________________________ Who Commissioned the System Company________________________________________________________________________ Street Address _______________________________...

Page 34: ...ers If spilled sweep up as much as possible then flush with water to drain KEEP OUT OF REACH OF CHILDREN NET CONTENTS 1 5 POUNDS 68 Kg Sea Recovery SRC MCC 1 Membrane Cleaning Chemical WARNING CONTAIN...

Page 35: ...ch as possible then flush with water to drain KEEP OUT OF REACH OF CHILDREN NET CONTENTS 1 5 POUNDS 68 Kg Sea Recovery SRC MCC 3 Membrane Cleaning Chemical WARNING CONTAINS SODIUM METABISULFITE HARMFU...

Page 36: ...uctivity in U S gallons per day by multiplying the gallon per hour product water flow meter reading by 24 6 Divide the figure reached in step 5 above present gallon per day productivity by the plotted...

Page 37: ...ture increases the Sea Recovery system pressure must be adjusted so that the system achieves no greater than 100 of rated product water flow Product water flow greater than 100 of rated capacity cause...

Page 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...

Page 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...

Page 40: ...Pre installation...

Page 41: ...rical disconnect switch is switched OFF LOCKED and TAGGED 3 A Volt Ohm Meter will be necessary WARNING ELECTRICAL SHOCK HAZARD The installation procedures expose the installer to High Voltage and elec...

Page 42: ...ng installed prior to within and after the Sea Recovery system must not contain iron The resulting failure of the R O Membrane Element is attributed to improper installation is the liability of the in...

Page 43: ...lves should be installed in this line A blockage or closed valve in the Product Water Line will cause extensive damage to the System and R O Membrane Element 6 Connection of the Sea Recovery Fresh Wat...

Page 44: ...System P ID Dual Prefilters Note Illustration shows the optional HP Pump PT Pressure Transducer PI Pressure Indicator M Meter FG Flow Gauge TDS TDS Meter P Pump PLC Program Loogic Controller Note Ref...

Page 45: ...stem P ID Commercial Prefilters Note Illustration shows the optional HP Pump Note Refer to the bigger drawing foldout at the end of this manual PT Pressure Transducer PI Pressure Indicator M Meter FG...

Page 46: ...ion examples N CONNECTION POINT DIAGRAM MAIN POWER FWF OPT BOOSTER PUMP SOFT START OPT HIGH PRESSURE PUMP MOTOR REMOTE TOUCH PAD OPT BRINE DISCHARGE HIGH PRESSURE HOSE CONNECTION DIFFERENTIAL TRANSDUC...

Page 47: ...ection examples STANDARD PREFILTER INSTALLATION BOOSTER PUMP CHARCOAL FILTER 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH...

Page 48: ...ILIZER INSTALLATION 3 8 OD TUBE 3 8 OD TUBE BOOSTER PUMP CHARCOAL FILTER 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD...

Page 49: ...ZER INSTALLATION 3 8 OD TUBE 3 8 OD TUBE BOOSTER PUMP CHARCOAL FILTER pH NEUTRALIZER OPTIONAL 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP M...

Page 50: ...TO BOATS PRESSURIZED FRESH WATER LINE 3 8 TANK OD TUBE TO INLET THRU HULL VALVE 3 4 OD TUBE BOOSTER PUMP SEA STRAINER PREFILTER FRESH WATER FLUSH OPTIONAL CHARCOAL FILTER PH NEUTRALIZER OPTIONAL 3 8...

Page 51: ...TUBE BOOSTER PUMP SEA STRAINER CHARCOAL FILTER 3 8 OD TUBE 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD...

Page 52: ...FILTER 3 8 OD TUBE 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD BRINE DISCHARGE UV STERILIZER OPTIONAL H...

Page 53: ...ER pH NEUTRALIZER OPTIONAL 3 8 OD TUBE 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD BRINE DISCHARGE UV ST...

Page 54: ...ALIZER OPTIONAL 3 8 OD TUBE 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD BRINE DISCHARGE UV STERILIZER OP...

Page 55: ...NEUTRALIZER OPTIONAL 3 8 OD TUBE 3 8 OD TUBE 3 8 OD TUBE TO POTABLE WATER TANK 3 4 OD TUBE 3 4 OD TUBE MAIN POWER FWF BOOSTER PUMP SOFT START HP PUMP MOTOR REMOTE TOUCH PAD BRINE DISCHARGE UV STERILIZ...

Page 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...

Page 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...

Page 58: ...ssure Transducer is always plumbed in the Feed Line at the appropriate location by the Installer and connected to the Differential Pressure Transducer with a 1 4 in 6 35 mm OD Tube by the Installer 3...

Page 59: ...t of the control panel informing the end user that The Reverse Osmosis Membranes Elements are not installed to contact the factory for the R O Membrane Elements and DO NOT operate the system without t...

Page 60: ...s and in turn provides lower system maintenance costs The Plankton Filter is available as a single housing or dual housing 7 Multi Media Filter This optional filter assembly contains a back washable b...

Page 61: ...ise and vibration This pump is exclusive and unique to the SRC systems Optional High Pressure Pump and Motor Assembly is a Radial Axial Positive Displacement Plunger Pump made of high grade Duplex mat...

Page 62: ...te measurement of Product Water quality 3 Flow Meter Product Water electronically measures the rate of Product Water flow in gallons or liters per hour 4 3 Way Product Water Diversion Valve Electric S...

Page 63: ...s sufficient Fresh Water to perform the Automatic Fresh Water Flush Cycle 2 Fresh Water Pressure Pump delivers fresh water throughout the boat or home In order to provide the required flow of water to...

Page 64: ...rol Logic that the Fresh Water Tank is full When installed and connected to the Main Printed Circuit Board the Fresh Water Tank High Level Switch must be connected as a N C Normally Closed 1PST One Po...

Page 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...

Page 66: ...Electrical...

Page 67: ...starts then the main High Pressure Pump Electric Motor starts Alternatively the Booster Pump and High Pressure Pump may be started manually by accessing the manual operation mode from the Touch Scree...

Page 68: ...86 0 5 3450 9 4 20 230 60 3 3450 12 7 43 0 5 3450 4 7 10 Three Phase Alternating Current High Pressure Pump Motor Booster Pump Motor VAC Hz H P RPM FLA LRA H P RPM FLA LRA 220 50 2 5 2850 7 9 24 9 0...

Page 69: ...or Length of run Voltage Phase Load 10 Ft 3 meter 25 Ft 8 meter 50 Ft 15 meter 110 115 VAC Single 9 4 Ampere 14 AWG 2 5 mm2 14 AWG 2 5 mm2 14 AWG 2 5 mm2 220 230 VAC Single 4 7 Ampere 14 AWG 2 5 mm2 1...

Page 70: ...49 0 0 4096 0 1317 10 4038 84 9683 0 0 3648 0 1045 9 2659 67 398 0 0 3249 0 0829 8 2525 53 4609 1 0 2893 0 0657 7 3482 42 3871 2 0 2576 0 0521 6 543 33 6069 3 0 2294 0 0413 5 8268 26 6516 4 0 2043 0 0...

Page 71: ...0829 8 2525 53 4609 50 1 0 2893 0 0657 7 3482 42 3871 40 2 0 2576 0 0521 6 543 33 6069 32 3 0 2294 0 0413 5 8268 26 6516 32 4 0 2043 0 0328 5 1892 21 1385 19 6 0 162 0 0206 4 1148 13 2913 13 8 0 1285...

Page 72: ...ose the installer to High Voltage and electrical shock hazard Only attempt this if you are a qualified electrician and only if surrounding conditions are safe Frame Enclosure Assembly Frame Enclosure...

Page 73: ...220 230 VAC RPM 50 Hz 2850 60 Hz 3450 VOLTAGE LINE A LINE B JOIN 220 230 VAC 1 4 2 3 110 115 VAC 1 3 2 4 NOTES 1 CONNECTIONS ARE SHOWN FOR CCW ROTATION FACING END OPPOSITE SHAFT EXTENSION STD FOR CW...

Page 74: ...E A MULTIPLE OF THOSE SHOWN ABOVE 4 LEAD COLORS ARE OPTIONAL LEADS MUST ALWAYS BE NUMBERED AS SHOWN ELECTRIC MOTOR WINDING WIRING DIAGRAMS THREE PHASE 50 60 Hz 220 230 VAC 380 460 VAC Sea Recovery HIG...

Page 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...

Page 76: ...06038F HP PUMP CONTACTOR 1 2 3131131500 ELEC TRANSFORMER 480 120 BUCK 1 3 B604170001 POWER SUPPLY ASSY 1 4 B604170000 DIN RAIL ASSY 1 3 1 2 4 ITEM NO PART NUMBER DESCRIPTION QTY 1 313106038F HP PUMP C...

Page 77: ...OCK HAZARD A Volt Ohm Meter will be necessary The following installation procedures expose the installer to High Voltage and electrical shock hazard Only attempt this if you are a qualified electricia...

Page 78: ...ctions If the Motor Soft Start is not already installed follow these instructions to install it 1 Disconnect the power source from the System 2 Open the System or Controller Enclosure cover to access...

Page 79: ...oft Start is not already installed follow these instructions to install it 1 Disconnect the power source from the System 2 Open the System or Controller Enclosure cover to access the Electrical Chassi...

Page 80: ...Electrical...

Page 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...

Page 82: ...Installation...

Page 83: ...and will avoid heat and abrasions from surrounding surfaces 1 Attach the supplied Inlet Connection to the Sea Cock Valve and rotate it towards the location of the Sea Strainer Inlet 2 Allow sufficien...

Page 84: ...r in approximately 26 lbs 12 kg of 20 silica sand The silica sand must always go on top of the gravel Clean the fill plug female threads of all debris and replace lid with a wrench lightly tightened N...

Page 85: ...Aqua Whisper DX Modular 450 1800 Page 5 3 Installation Figure 5b Follow the labeling NOT the molded arrows and lettering...

Page 86: ...ten an additional 45 degrees DO NOT OVER TIGHTEN OVER TIGHTENING WILL STRIP THE MANIFOLD FEMALE THREADS Using the supplied 1 4 in 6 35 mm O D tubing connect the center Pressure Differential Transducer...

Page 87: ...tion with the supplied hose clamps Ensure all Suction Hose connections use two hose clamps rotated 180 degrees with the screw heads facing the same direction Remove any flash on the Hose Barb fittings...

Page 88: ...or that they system has shut down Fresh Water Tank Low Level Switch owner installer supplied provides an optional feature to the System Control Logic that works in conjunction with the Automatic Fresh...

Page 89: ...1 Away from water lines and hoses 2 Away from locations subject to water spray 3 In an accessible and viewable location 4 Within 80 ft 24 4 m of the Main Control Panel 5 6 ELECTRICAL CONNECTIONS Refer...

Page 90: ...lost Drill Bits Deep Well Pump If the System Booster Pump will be used then Size the Well Pump to Deliver Minimum 5 psi maximum 10 psi into the inlet of the Booster Pump or If the System Booster Pump...

Page 91: ...y or vertically For vertical installation make sure the inlet port is positioned at the bottom Installation Procedure NOTE Do not assemble or install damaged parts Quartz sleeve and UV lamp are fragil...

Page 92: ...he O ring has all round contact with the cylinder pass thru 8 Tighten the compression nut while making sure the nut does not contact the quartz sleeve Adjust O ring position as necessary The compressi...

Page 93: ...ow the inlet water temperature to drop below 35 F 2 C d Do not allow the flow rate to exceed 2 GPM 7 5 LPM e Do not cycle the UV unit more than 3 ON OFF cycles in a 24 hour period f Ensure all plumbin...

Page 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...

Page 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...

Page 96: ...Commissioning...

Page 97: ...ailure to follow these instructions will lead to system failure and cause damage to components 6 1 CHECK INSTALLATION Ensure that the installation has been properly performed Do not rely on the instal...

Page 98: ...g the number of days 5 LANGUAGE Changes the current language used on the controller by selecting new language option 6 UNIT Toggles the measurement standards between U S Standards and Metric Standards...

Page 99: ...lick when repositioning 6 5 OPERATION NOTES BEFORE starting the System in semi auto mode be prepared for the following sequence After the System has been started the following will occur CAUTION The o...

Page 100: ...and count down until the next automatic Fresh Water Flush Cycle The Fresh Water Flush Cycle will automatically initiate every preset number of days until canceled or power is disconnected from the Sy...

Page 101: ...cing Product Water the Product Water may not be Potable for up to 30 minutes The salinity of the Product Water diminishes gradually until it reaches the acceptable level or lower PRODUCT SALINITY RED...

Page 102: ...d Abnormal noises or other occurrences 11 If any abnormality develops touch the STOP button on the Touch Screen A warning screen will display a Correct the problem then repeat Step 1 10 12 Proceed to...

Page 103: ...automatically In order to perform a manual Fresh Water Flush follow the directions in Section 7 3 BOAT SAFETY WARNING The Inlet Thru Hull Sea Cock Valve is in the Open position It is recommended for t...

Page 104: ...Way Diversion Solenoid Valve will de energize the UV Sterilizer will de energize the High Pressure Pump will stop and the Booster Pump will stop If the Automatic Fresh Water Flush option is installed...

Page 105: ...______________________________________ Who Commissioned the System Company________________________________________________________________________ Street Address ______________________________________...

Page 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...

Page 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...

Page 108: ...Operation...

Page 109: ...ERATION IMPORTANT Notes regarding the Automated operational sequence NOTE During operation touching STOP at any time immediately stops all functions of the System Touch STOP ONLY in case of an emergen...

Page 110: ...rated within the next 2 weeks FREEZING TEMPERATURE WARNING The System must be protected from freezing if it will be exposed to temperatures below 32 Fahrenheit 0 Celsius Freezing temperatures below 32...

Page 111: ...t be controlled by the System Logic and must be controlled by the operator All Operating Screens WILL NOT include the Automatic Fresh Water Flush components if the Fresh Water Flush Option is not inst...

Page 112: ...the SETUP tab 3 On the next screen touch the Acceptable Salinity Level button 4 On the Salinity Level screen adjust to desired level 200 to 1000 PPM then touch the SETUP button 5 On the next screen to...

Page 113: ...e illustrations may be referred to during the Rinse Clean and Storage procedures The illustration on Page 7 8 figure 7c demonstrates a simplified Once Through Configuration This is used to Rinse the S...

Page 114: ...this section state configure for Once Through Rinse refer to page 7 7 figure 7a and proceed as follows 1 Configure the Suction line for a Once Through Configuration as illustrated on Page 7 7 Disconn...

Page 115: ...Aqua Whisper DX Modular 450 1800 Page 7 7 Operation Note The above illustrations show representations of components and may not show actual or all components Figure 7b Figure 7a...

Page 116: ...per DX Modular 450 1800 Page 7 8 Operation Figure 7c Simplified Aqua Whisper DX Once Through Rinse Aqua Whisper DX R O System Aqua Whisper DX R O System Figure 7d Simplified Aqua Whisper DX Re Circula...

Page 117: ...w or the R O membrane element has ITEMS REQUIRED a 20 gallons 75 7 liters of potable water b Sea Recovery Storage Chemical SRC SC c 2 Gallons 7 5 liters of food grade glycerin propylene glycol if the...

Page 118: ...ay be some mineral fouling combined with biological fouling dried out prior to use A NEW System experiencing low production should be operated for up to 48 hours continuously to clear and saturate the...

Page 119: ...eting the Water in the Bucket Touch STOP 7 Once again fill the container with 10 gallons 37 8 liters clean fresh water 8 Add to the 10 gallons 37 8 liters of fresh water 1 5 lbs 0 68 kg of Sea Recover...

Page 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...

Page 121: ...e Transducer 2 ________ psi or ________ kPa High Pressure Transducer ________ psi or ________ kPa WATER FLOW METER READINGS Flow Meter Product Water ________ US Gallons Per Hour or ________ Liters Per...

Page 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...

Page 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...

Page 124: ...Maintenance...

Page 125: ...he system ensure that they are rinsed thoroughly wiped and dried prior to reassembly After the components have been reassembled 8 MAINTENANCE AND REPAIR From time to time Sea Recovery may make program...

Page 126: ...ull so as to allow free flowing Feed Water without air CAUTION A flat profile flush mount inlet thru hull fitting will cause a vacuum as the boat is under way and this will cause loss of feed water fl...

Page 127: ...ttributed to improper installation is the liability of the installer and is not covered by the Sea Recovery warranty CAUTION If the thru hull fitting has been placed in a position on the underside of...

Page 128: ...ecovery warranty Plumb the Sea Recovery System to the bottom of such feed water arrangements to ensure a continual air free supply of feed water to the system 2 Sea Cock Valve Non Sea Recovery compone...

Page 129: ...ubrication from time to time If your Electric Motor has grease jerks at each end of the motor over the front and rear bearings the bearings require lubrication every 6 months Give three pumps of high...

Page 130: ...stem will turn off and display a fault screen Base or Shell Dolium R Polyurea Base DO NOT USE LITHIUM OR SILICONE BASE GREASE 7 T Connector Pressure Pick Up Replace any hose or tube that is kinked Dis...

Page 131: ...ts Any debris entering the Pump will cause extensive and expensive damage to the internal parts The Sea Recovery Prefilter will stop any debris and protect the High Pressure Pump Use caution when chan...

Page 132: ...rts The Sea Recovery Prefilter will stop any debris and protect the High Pressure g Insert the cleaned or new Sea Recovery Commercial Prefilter Pleated Cartridge Element into the bowl h Replace the li...

Page 133: ...rotor amperage not rotate and trip the supply power circuit breaker when attempting to operate the System Low voltage will also cause the same symptom Low voltage is caused by an undersized power Pum...

Page 134: ...unusual grinding sound when operated Solutions a Check and replace as necessary the front and rear bearings b Check to see if the fan is rubbing against the fan guard B High Pressure Pump Optional Pu...

Page 135: ...minated the HP terminals on the Control Printed Circuit Board should receive 12 VDC If it is not the case replace the main circuit board A Pressure Pump requiring maintenance within the warranty perio...

Page 136: ...g h Insert all three of the Socket Head Cap Screws 16 finger tight back into the End Plug 3 4 These screws are used as a grip to remove the End Plug i Grasp one or more of the Socket Head Cap Screws w...

Page 137: ...Vessel Assembly Refer to page 8 11 17 Figure 8c R O Membrane illustration of brine seals Left side Inlet Feed Water Entry R O Membrane Element Brine Seal End Right Side Outlet Brine Discharge No brine...

Page 138: ...the respective fitting on the Pressure Vessel 18 High Pressure Manifold Replace the High Pressure Manifold if it is visibly cracked or broken and leaking Replace High Pressure fitting O rings if dama...

Page 139: ...B 11 If air expels from port B then valve need to be replaced C Solenoid Valve Coil Check 1 The 3 way Product Diversion Valve Solenoid operates from 12 VDC To check the condition of the Diversion Val...

Page 140: ...lements on the market are designed for a very low flow rate and will cause extensive and expensive damage to the Sea Recovery System resulting from several hundred pounds of pressure build up on the p...

Page 141: ...tz Sleeve Cleaning a Remove the four screws on the ballast box and remove lid b Remove the rubber boot and carefully pull lamp out of the quartz sleeve c Unscrew and remove the two compression nuts ba...

Page 142: ...per 24 hour period Exceeding 3 cycles will subjected the lamp filament to excessive thermal stress leading to premature failure of the UV lamp Unit Maintenance The exterior surfaces of the UV unit sho...

Page 143: ...mains after rinsing the quartz sleeve should be replaced Contact your local CSR to order a replacement NOTE Failure to perform quartz sleeve maintenance may reduce the efficiency of the UV light to ad...

Page 144: ...low water quality water and less frequently for systems operating with low flow rate or high water quality UV Unit Specifications Type 12 VDC Operating UV Sterilizer for 2 gallon 7 5 liters per minut...

Page 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...

Page 146: ...Troubelshooting...

Page 147: ...he occurrence is the correct one When the test has confirmed the source of the problem the appropriate remedy is given to correct it There may be more than one cause of a problem In the following guid...

Page 148: ...The Sea Recovery System must not be tied into another existing auxiliary water line already supplying another accessory on the boat Using one Thru Hull fitting for other equipment will cause the Sea...

Page 149: ...r can enter the feed line causing the System to lose pressure Look for air bubbles moving through the Sea Strainer or feed line Solution Change the valve seals tighten them or if necessary replace the...

Page 150: ...0 hours of use If left unused for extended periods of time seal replacement may be required sooner Solution Replace seal 3 INLET CONNECTOR AS WELL AS ALL FITTINGS AND CONNECTIONS PRIOR TO THE INLET OF...

Page 151: ...t through a 20 micron cartridge filter element then through a 5 micron cartridge filter element By stepping the filtration both prefilter elements gain longer life and require less maintenance labor a...

Page 152: ...sed by the Prefilter a The Feed Water Pressure into the Prefilter is higher than normal and the Feed Water Pressure into the High Pressure Pump is lower than normal replacement cost As the cartridge f...

Page 153: ...ng is adequate Over tightening will stress the threads on the base and the lid locking ring causing them to crack The pressure differential readings across the Prefilter indicate that the element is f...

Page 154: ...nd Symptoms appearing and caused by the Oil Water Separator a The Feed Water Pressure into the Oil Water Separator is higher than normal and the Feed Water Pressure into the High Pressure Pump is lowe...

Page 155: ...ase Generator power to Three Phase Shore power ALWAYS check phases prior to operating the System else Reverse Rotation along with extensive damage to the High Pressure Pump will occur should the power...

Page 156: ...h Pressure Hose has been assembled with crimp fittings by Sea Recovery The High Pressure Hose is NOT The pump will make a grinding noise if its drive shaft has been forced into the pump body The Elect...

Page 157: ...ly over months decreases and Product Water Salinity slowly over months increases quality decreases repairable Should a leak damage or failure develop replace the High Pressure Hose Solutions Replace a...

Page 158: ...e element s from prematurely fouling The System Control Logic will also not allow the System Operating pressure to exceed 950 PSI 66 BAR As the Reverse Osmosis Membrane Element is exposed operated or...

Page 159: ...l range that it must measure The full range of salinity that the probe must attempt to measure is from 5 to 2000 PPM at 34 to 122 F 1 to 50 Celsius Always reference the This protects the R O Membrane...

Page 160: ...on Solenoid Valve does not switch to Potable Water even though the Touch Pad indicates that the System is OK performing normally and producing Potable Product Water probe accuracy and calibration to 8...

Page 161: ...water back to a normal of pH 7 5 The life of the neutralizing cartridge depends on the amount of use amount of product water flowing through it Replace the element as necessary CAUTION Use only Sea Re...

Page 162: ...isolate the fresh water from the feed water c Fresh Water Flush Carbon Filter removes chlorine if present in the fresh water prior to flowing through the R O Membrane Element d Feed water Check Valve...

Page 163: ...are operated by touching the screen and where all operating conditions are monitored Problems and Symptoms appearing and caused by the Touch Pad a The Touch Screen blacks out or whites out Extreme te...

Page 164: ...utomatic Fresh Water Flush option When installed and connected to the Main Printed Circuit Board the Fresh Water Tank Low Level Switch must be connected as a N O Normally Open 1PST One Pole Single Thr...

Page 165: ...h Pressure Pump Contactor T Terminal d High Pressure Pump Contactor L Line e Main Terminal Strip power from Power Source to Contactor Check for Control Voltage at the Terminal Strip 3 Booster Pump Con...

Page 166: ...of the line For example when determining why a Booster Pump is not operating first check the voltage at the Booster Pump and work your way back to each component checking for voltage across each conne...

Page 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...

Page 168: ...Parts View...

Page 169: ...ows us to determine the specific sequential operation of the system based on the version of the programmed control logic AND provide us with information on the part that you wish to order Part Number...

Page 170: ...ting Specify Tube Size Specify Pipe Size Specify Male or Female Connector Male 1 4 O D 1 4 MNPT or FNPT Connector Female 3 8 O D 3 8 MNPT or FNPT Elbow 90 Male 1 2 O D 1 2 MNPT or FNPT Elbow 90 Female...

Page 171: ...3 4 50 00 FEET 14 0101013783 ELB90 3 4 FPT X 3 4 FPT PVC 1 00 EACH 15 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC 3 00 EACH 16 0421051239 SEA STRAINER 3 4 BRONZE 1 00 EACH 17 0101073783 ELB90 3 4 MPT X 3 4...

Page 172: ...ITEM 1 SCREW 1 4 20 X 5 8 HS NOT SOLD SEPARATELY 4 EACH 8 PART OF ITEM 1 WASHER 1 4 PFW 2 SET NOT SOLD SEPARATELY 4 EACH 9 PART OF ITEM 1 O RING DRAIN PLUG NOT SOLD SEPARATELY 1 EACH 10 PART OF ITEM 1...

Page 173: ...EACH 16 061010057000 Nut Hex 3 8 SS 7 EACH 17 569030012A SCREW HEX 5 16 18 X 2 1 2 7 EACH 18 26141260PP GASKET BOOSTER PUMP N200 1 EACH 19 061142157016 BOLT HEX 3 8 16 X 1 SS 2 EACH 20 5680010001A MO...

Page 174: ...230 50 60 1PH 1 EACH 3 061080056000 WASHER FLAT 3 8 SS 4 EACH 4 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC 1 EACH 5 0101073783 ELB90 3 4 MPT X 3 4 BARB PVC 1 EACH 6 063200066000 NUT LOCK 1 2 STEEL 1 EACH...

Page 175: ...ER FLAT 3 8 SS 4 EACH 5 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC 1 EACH 6 3131210495 WIRE NUT YELLOW 3 EACH 7 063200066000 NUT LOCK 1 2 STEEL 1 EACH 8 1920023632 STRAIN RELIEF 90 CG90 6250 1 EACH 9 3131...

Page 176: ...83 UNION 3 4 FNPT X 3 4 FNPT PVC 1 EA 18 0101343783 PLUG 3 4 MNPT PVC 2 EA 19 20200404010 BRACKET L MOUNTING FEET 4 EA 20 061172143016 SC HEX A 1 4 X 1 SS 8 EA 21 061100043000 WASHER FLAT OS 1 4 SS 8...

Page 177: ...A FILTER INLET PIPING TO MEDIA FILTER OUTLET PIPING 22 21 20 19 22 21 24 23 27 28 25 26 9 15 16 17 18 15 11 16 17 10 MEDIA SAND A1000 25 POUNDS MEDIA GARNET 8 12 15 POUNDS 31 30 29 18 12 13 20 Note It...

Page 178: ...4 SL X 3 4 X 3 4 SL 4 EA 5 0101323483 REDUCER BUSHING 3 4 SL X 1 4 FT PVC 2 EA 6 0101652683 ADAPTER 1 2 MT X 3 4 BARB PVC 3 EA 7 0204020869 ELBOW 90 1 2 MT X TUBE PLASTIC 2 EA 8 0101313683 REDUCER BUS...

Page 179: ...EA 2 PART OF ITEM 1 BOWL 10 INCH PREFILTER BLUE HOUSING NOT SOLD SEPARATELY 1 EA 3 2614010473 O RING 237 10 INCH PREFILTER BLUE HOUSING 1 EA 4 0805823578 ELEMENT PLANKTON 1 EA 5 20200402100 BRACKET PR...

Page 180: ...UE HOUSING 2 EA 4 0805823578 ELEMENT PLANKTON 2 EA 5 20200402100 BRACKET PREFILTER CHRCL PLNKTN 2 EA 6 061170628016 SC PHIL PAN A 10 X 1 SS 8 EA 7 065080028000 WASHER FLAT 10 NYLON 8 EA 8 01013737CL N...

Page 181: ...MAGE TO THE HIGH PRESSURE PUMP AS WELL AS PREMATURE FOULING OF THE R O MEMBRANE ELEMENT Damage caused to the Sea Recovery High Pressure Pump R O Membrane Element or any other component from the use of...

Page 182: ...PRE FILTER CHRCL PLNKTN 1 3 0801130257 ELEMENT PREFILTER 10 25 1 4 0801060157 ELEMENT PREFILTER 10 05 1 5 0112072600 ELBOW 50 MPT X 3 4 BARB NYLON 2 6 061170628016 SC PHIL PAN A 10 X 1 SS 8 7 0610800...

Page 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...

Page 184: ...FT 1 EA 4 07620310WA 06 O RING LID CPF OWS 32 5 SQ FT 1 EA 5 07620310WA 01 BASE FILTER HOUSING 32 5 SQ FT 1 EA 6 22130102BE LABEL COMM PRE FILTER 2 EA 7 2234011260 LABEL INLET SRC BLUE 1 EA 8 22340113...

Page 185: ...11 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC 2 EA 12 05181434AA HOSE CLAMP 3 4 SS 4 EA 13 061172143016 SC HEX A 1 4 X 1 SS 4 EA 14 061100043000 WASHER FLAT OS 1 4 SS 4 EA 15 0204020100 ELB90 1 4 TUBE JG...

Page 186: ...c Cavitation to the high pressure pump resulting in premature failure of the pump d Extensive Line Pressure Build Up in the High Pressure Hoses and Manifolds d Telescoping damage of the R O Membrane E...

Page 187: ...OTOR MOUNT MODULAR 1 4 061060057000 NUT HEX 3 8 16 W INSERT SS 4 5 061142157028 BOLT HEX 3 8 16 X 1 3 4 SS 4 6 2115031020 1 RUBBER MOTOR MOUNT 40LB 4 7 2115031020 2 RUBBER MOTOR MOUNT 40LB 4 8 1218051...

Page 188: ...200239001 PLATE MOTOR MOUNT AQM II MODULAR 1 4 061060057000 NUT HEX 3 8 16 W INSERT SS 4 5 061142157028 BOLT HEX 3 8 16 X 1 3 4 SS 4 6 2115031020 1 RUBBER MOTOR MOUNT 40LB AQM II 4 7 2115031020 2 RUBB...

Page 189: ...00239001 PLATE MOTOR MOUNT AQM II MODULAR 1 4 061060057000 NUT HEX 3 8 16 W INSERT SS 4 5 061142157028 BOLT HEX 3 8 16 X 1 3 4 SS 4 6 2115031020 1 RUBBER MOTOR MOUNT 40LB AQM II 4 7 2115031020 2 RUBBE...

Page 190: ...HT iTEM PART DESCRIPTION 1 52 12180513C0 RIGHT PUMP HP 4 2 GPM SS RIGHT COMPLETE HP PUMP 1 29 12180512C0 CCAR DRIVE END PUMP HP 4 2 GPM SS RIGHT STUFFED CRANKCASE SECTION 30 52 12180511C0 WE WET END P...

Page 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...

Page 192: ...000 NUT HEX 3 8 16 W INSERT SS 4 8 061142157028 BOLT HEX 3 8 16 X 1 3 4 SS 4 9 NOT USED 10 2115031020 1 RUBBER MOTOR MOUNT 40LB 4 11 061080056000 WASHER FLAT 3 8 SS 8 12 15AE261912 MOTOR 3 2 5 HP 115...

Page 193: ...LER TX1 1 8 353033002A O RING 017 1 9 061120091000 WASHER SPLIT LOCK M6 SS 2 10 061142191174 HEX BOLT M6 X 20MM SS 2 11 1220770103 BELL HOUSING AQ AW 3PH 1 12 0117372530 NIPPLE 1 2NPT X 3 0 LG SS 1 13...

Page 194: ...SY AQMC AQTC 700 1 14 1 4 362mm OUTLET B390120005 HOSE HP ASSY AQMC AQTC 900 1 23 3 4 603mm NLET B390120006 HOSE HP ASSY AQMC AQTC 900 1 17 3 4 451mm OUTLET B390120007 HOSE HP ASSY AQMC AQTC 900 2 17...

Page 195: ...O RING 116 PRODUCTAS AW 2 EACH 14 2614014900 O RING 230 BRINE 3 END PLUG 4 EACH 15 2234011360 LABEL OUTLET SRC BLUE 1 EACH 16 2234011260 LABEL INLET SRC BLUE 1 EACH 17 2220010660 LABEL MEMBRANE SERIAL...

Page 196: ...SPER DX 900 1 26 B390120005 HOSE HP ASSY AQMC 900 1 23 75 INLET 1 EACH 27 B390120006 HOSE HP ASSY AQMC 900 1 17 75 OUTLET 1 EACH 28 2408132500 02 VESSEL HIGH PRESSURE 900GPD AW 1 EACH 29 30 2724011433...

Page 197: ...AW 4 EACH 12 061162345012 SC SOC CAP 1 4 20 X 3 4 SS 12 EACH 13 0101370815 NIPPLE 1 4 NPT X 1 1 2 PVC 2 EACH 14 0204010869 ELB90 1 4 TUBE X 1 4 FPT PLAST 2 EACH 15 2614010100 O RING 116 PRODUCTAS AW...

Page 198: ...500 01 VESSEL HIGH PRESSURE 700GPD AW 2 EACH 32 33 2724011333 MEMBRANE 700GPD AW W BRINE SEAL 2 EACH 33 2614050433 BRINE SEAL 3 FOR AQUA WHISPER 1800 2 29 B390120011 HOSE HP ASSY AQMC 1800 2 23 75 INL...

Page 199: ...MAGE TO THE HIGH PRESSURE PUMP AS WELL AS PREMATURE FOULING OF THE R O MEMBRANE ELEMENT Damage caused to the Sea Recovery High Pressure Pump R O Membrane Element or any other component from the use of...

Page 200: ...URE PLATE DIVIDER AQWM III AQMM II 1 3 1904010743 STRAIN RELIEF 3219 BLK 3 4 1904010643 STRAIN RELIEF 3444 BLK 1 5 3131101300 PLUG BLANKING REMOTE AQM 625 1 6 1904010343 STRAIN RELIEF 3223 3 4 GREY 3...

Page 201: ...ge 10 33 Parts View 22 CONTROLLER CHASSIS ASSY SINGLE PHASE B619940001 ITEM NO PART NUMBER DESCRIPTION QTY 1 313106038F HP PUMP CONTACTOR 1 2 31318301DX EMI FILTER 1 3 B604150002 POWER SUPPLY ASSY 1 4...

Page 202: ...Parts View ITEM NO PART NUMBER DESCRIPTION QTY 1 313106038F HP PUMP CONTACTOR 1 2 3131131500 ELEC TRANSFORMER 480 120 BUCK 1 3 B604150002 POWER SUPPLY ASSY 1 4 B604150001 DIN RAIL ASSY 1 23 CONTROLLER...

Page 203: ...PTION QTY 1 B515160001 LP ASSY 1 2 2020083000 PLATE WET AQW DX COMPACT 1 3 0501164800 PIPE SUPPORT 3 8 1 4 0501164900 PIPE SUPPORT 3 4 2 5 0501164400 PIPE SUPPORT 1 1 6 061170617016 SC PHIL PAN B 6 X...

Page 204: ...1 4 MPT PLASTIC 1 9 0204012469 ELB90 1 2 TUBE X 3 8 FPT PLASTIC 1 10 0101371830 NIPPLE 3 8 NPT X 3 PVC 1 11 0204021969 ELB90 3 8 TUBE X 1 2 MPT PLASTIC 1 12 01015518HR COUPLER 3 8 FPT X 3 8 FPT PVC 2...

Page 205: ...0001 ITEM NO PART NUMBER DESCRIPTION QTY 1 2317100200 TRANSDUCER 0 200 PSI 7 16 SAE 1 2 0112652500 ADAP 1 2 MNPT X 1 2 BARB NYLON 2 3 0101342583 PLUG 1 2 MPT PVC 1 4 590111401A PLUG 7 16 14 O RING BOS...

Page 206: ...s View ITEM NO PART NUMBER DESCRIPTION QTY 1 5301400801 MANIFOLD LP PICKUP AQM II 1 2 2317100200 TRANSDUCER 0 200 PSI 7 16 SAE 1 3 0112652500 ADAP 1 2 MNPT X 1 2 BARB NYLON 2 4 0101342583 PLUG 1 2 MPT...

Page 207: ...W 2 4 2614017900 O RING 115 INTERCONNECT AW 4 5 061170618109 SC PHIL PAN A 6 X 75 SS 2 6 10181421CC GAUGE 0 1400 CBM ORING SEAL 1 7 2614015800 ORING 011 GAUGE PRES SWITCH 2 8 0117230869 ELB90 ST 25 MP...

Page 208: ...51950AS ELEMENT PH 9 3 4 1 4 0803004773 CHARCOAL FILTER 10 IN 1 5 0204021869 ELB90 3 8 TUBE X 3 8 MPT PLASTIC 2 6 061170628016 SC PHIL PAN A 10 X 1 SS 8 7 061080028000 WASHER FLAT 10 SS 8 8 0611421450...

Page 209: ...026000 NUT HEX 8 32 W INSERT SS 4 EA 061161626012 SC PHIL FLAT 8 32 X 3 4 SS NOT SHOWN 4 EA 061170628016 SC PHIL PAN A 10 X 1 SS NOT SHOWN 8 EA 8 065080028000 WASHER FLAT 10 NYLON 8 EA 9 20200404040 B...

Page 210: ...783 TEE 75 FNPT x 75 FNPT x 75 FNPT PVC EACH 1 13 0101653783 ADAP 3 4 MPT X 3 4 BARB PVC EACH 2 14 0501164200 PIPE SUPPORT 1 1 8 36 EACH 1 15 0501164500 PIPE SUPPORT 1 1 4 EACH 1 16 01013737CL NIPPLE...

Page 211: ...Aqua Whisper DX Modular 450 1800 Page 10 43 Parts View 25 13 17 15 21 14 16 12 22 19 18 10 9 7 5 6 8 26 3 4 20 1 2 24 27 11 23 28 FRESH WATER FLUSH 50 INCH B598000008 Illustration...

Page 212: ...t Clean Rinse Kit 2 2 20010418001A Bracket Mount Saddle UV AW Top 2 3 061142150016 Bolt Hex 1 4 20X1 1 4 SS 2 4 061100043000 Washer Flat OS 1 4 SS 2 5 065070045000 Nut Locking 1 4 20 Flanged Nylon 2 6...

Page 213: ...U M B610140001 PROGRAMMING KIT DEALER 1 EA 1 B610140002 REMOTE KIT 45FT 1 EA 2 B610140003 REMOTE KIT 100FT 1 EA 3 B610140004 NMEA INTERNAL CONNECTION KIT 1 EA 4 B610140005 NMEA CONNECTION WITH REMOTE...

Page 214: ...Aqua Whisper DX Modular 450 1800 Page 10 46 Parts View 34 SOFT START ASSY ITEM PART NUMBER DESCRIPTION QTY U M 1 B596800006 SOFT START ASSY AW 1 EACH...

Page 215: ...Sheet 11 1 Standard P ID PT Pressure Transducer PI Pressure Indicator M Meter FG Flow Gauge TDS TDS Meter P Pump PLC Program Logic Controller Note Illustration shows the optional HP Pump 11 FOLDOUT...

Page 216: ...Sheet 11 2 Commercial P ID PT Pressure Transducer PI Pressure Indicator M Meter FG Flow Gauge TDS TDS Meter P Pump PLC Program Logic Controller Note Illustration shows the optional HP Pump...

Page 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...

Page 218: ...Sheet 11 4 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase with Soft Start...

Page 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...

Page 220: ...Sheet 11 6 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase with Soft Start...

Page 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...

Page 222: ...Sheet 11 8 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase with Soft Start...

Page 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...

Page 224: ...Sheet 11 10 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase with Soft Start...

Page 225: ......

Page 226: ...Part Number B651930002 Sea Recovery Corporation P O Box 5288 Carson CA 90745 5288 sales searecovery com www searecovery com...

Reviews: