Aqua Whisper DX Modular 450-1800
Page 5-10
Installa
tion
NOTE
! To remove
tube from fitting, first
remove the C-clamp
then push fitting
sleeve down. Once
the fitting sleeve is
down, pull the tube out of the fitting.
Install Ultraviolet Lamp
Perform this procedure only after the quartz sleeve
installation and leak-tests are completed successfully
1.
Connect the UV lamp to the 4-point receptacle.
If the lamp is not installed properly, lamp breakage
will occur.
2.
Insert lamp into quartz sleeve through
compression nut pass-thu.
3.
Install rubber boot over compression nut.
4.
Connect unit power cable to power source.
5.
Tighten the 4 screws to secure ballast box cover.
6.
Turn ON the power to the unit.
7.
Verify UV lamp operation from the viewport.
8.
Allow one minute for the UV lamp to warm up prior
to flowing water through the UV unit.
CAUTION
! Use the viewport to verify the
proper operation of the UV lamp.
7.
Lubricate the tips of the quartz sleeve with clean
water and insert new O-ring. Ensure the O-ring
has all-round contact with the cylinder pass-thru.
8.
Tighten the compression nut while making sure
the nut does not contact the quartz sleeve. Adjust
O-ring position as necessary. The compression nut
should be snug and tight, not over-torque.
9.
Repeat Step 7 and 8 on the ballast box
compression nut.
Connect Plumbing
Tube or hose ends must be cut squared and clean; must
have no rough edges. The quick fit elbow fitting has a
C-clamp that will lock the tube in place once inserted.
1.
Insert the supply pipe into one cylinder port and
label the port “Inlet”.
2.
Insert the temporary pipe into the other cylinder
port to direct water into a container.
3.
Slowly fill the cylinder with water and flush
cylinder for 1 minute.
4.
Remove temporary pipe and insert the return pipe
into the cylinder port and label the port “Outlet”.
5.
Slowly pressurize the UV unit by filling the cylinder
with water while checking for leaks.
6.
If leaks are found on the compression nuts,
depressurize the unit and slightly tighten the
leaking compression nut.
7.
Retest until a leak-free installation is verified.
8.
Once UV unit is leak-free, the quartz sleeve
installation is complete and the UV lamp can
be installed.
Summary of Contents for Aqua Whisper DX 1400-2
Page 2: ......
Page 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Page 4: ......
Page 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Page 12: ...Introduction...
Page 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Page 16: ...Description...
Page 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Page 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Page 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Page 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Page 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Page 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Page 40: ...Pre installation...
Page 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Page 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Page 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Page 66: ...Electrical...
Page 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Page 80: ...Electrical...
Page 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Page 82: ...Installation...
Page 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Page 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Page 96: ...Commissioning...
Page 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Page 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Page 108: ...Operation...
Page 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Page 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Page 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Page 124: ...Maintenance...
Page 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Page 146: ...Troubelshooting...
Page 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Page 168: ...Parts View...
Page 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Page 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Page 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Page 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Page 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Page 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Page 225: ......