Procedure, Radome Strain Relief Installation
4.2
Making the holes
PLANNING: Space has been allowed for
up to 5 ea. strain reliefs, but, install only
as many as needed. (Typically only 2-3
B
for
TX/RX systems). Refer to Fig 2 then plan
which hole positions to use.
For 76-inch radomes lowest holes may
be approx 1.5 inches from inside wall
corner with floor (ref drawing 129416).
Note:
The
hole
center-to-center distance
given is the MINIMUM.
Follow
good engineering practice and
provide the largest spacing possible
D
between holes as follows:
1 Hole pattern -
"A".
2 Hole pattern -
"B", "C".
3 Hole pattern - "A", "B", "C", ("A", "D", "E" PERMITTED).
4 Hole pattern - "B", "C", "D", "E".
5 Hole pattern - “A”, "B", "C", "D", "E".
A
C
E
Fig. 2 – Planning
Measure in place or use
template drawing 132234
Fig. 3 – (Up to) 5-Hole Pattern
Page 2 of 6
Document No
131226 Rev A
Form # 117140-B
Summary of Contents for 6012-12w
Page 101: ......
Page 102: ......
Page 103: ......
Page 106: ...8 7 6 5 4 D 5 C B A 8 7 6 5 4 ...
Page 116: ...8 7 6 5 4 3 50 58 58 59 2X 1 52 58 58 59 2X ...
Page 120: ......
Page 128: ......
Page 129: ......
Page 130: ......