6012-12W Installation Manual
Installation
Pin 5
GND
Pin6
N/C
Pin 7
GND
Pin 8
TX+ NMEA
Pin 9
+12 VDC (
125ma MAX
)
If your NMEA 0183 Gyro Compass outputs RS-422:
Connect its’ TX+ output to J10 pin 1 (RX+)
Connect its’ TX- output to J10 pin 2 (RX-)
If your NMEA 0183 Gyro Compass outputs RS-232:
Connect its’ GND output to J10 pin 1 (RX+)
Connect a jumper from pin 1 to J10 pin 5 (GND)
Connect its’ TXD output to J10 pin 2 (RX-)
J12 Aux 232 -
Auxiliary wired RS-232 connection. Wiring is:
Pin 1 - GND
Ground
Pin 2 - Aux IN1
Modem Lock Input 1 - See modem setup chapter.
Pin 3 - Aux IN2
Modem Lock Input 2 - See modem setup chapter.
Pin 4 - GND
Ground
Pin 5 - SW1
Blockage/Modem Mute Output 1 - See blockage & modem setup
chapters.
Pin 6 - SW2
Blockage/Modem Mute Output 2 - See blockage & modem setup
chapters.
Pin 7 - SW3A
Dry Contact set 2 - Dry alarm contacts used to provide
Pin 8 - SW3B
(programmable) alarm output to other equipment/systems.
Switched outputs have ability to use 4.7K pull up or Pull Down and
can provide Current sink of 0.5 amps max. Contacts are
Normally
Open
for No Alarm state and are
Closed/Shorted
when the
programmed alarm state exists.
Pin 9 - SW4A
Dry Contact set 1 - Same as dry alarm contact set 2.
Pin 10 - SW4B
J14 Aux 232 -
Antenna M&C Serial connections. The +12 VDC output is only intended to power a
very low current consumption device, do NOT exceed
125ma MAX.
Wiring is:
Pin 1
N/C
Pin 2
RD
Pin 3
TD
Pin 4
N/C
Pin 5
GND
Pin6
N/C
Pin 7
RTS
Pin 8
CTS
Pin 9
+12 VDC (
125ma MAX
)
3-10
EAR Controlled - ECCN EAR99