6012-12W Installation Manual
6012-12w Technical Specifications
SSPB
Gilat 12w
Output Flange
WR-75
Input Connector
Type F
RF Input Frequency Range
950 to 1450 MHz
RF Output Frequency Range
14.0-14.5 GHz
RF Output VSWR
2.5:1 max
RF Pout@ 1 dB GCP
41 dBm (12 Watt BUC)
Reference Frequency Level
-5 to +5 dBm
Reference Frequency
10 MHz ext
M&C Options
NONE
Step attenuator
1db Increments
Alarms
NONE
LNB, KU-Band PLL
NJR2535S - 122188-1
Voltage Required
15VDC to 24VDC
Input RF Frequency
11.70 to 12.20 GHz
Local Oscillator Frequency
10.75 GHz
Output IF Frequency
950 - 1,450 MHz
Power Supply (ADE / PCU /
ICU)
A/C Input Voltage
85-264 VAC, 47-63Hz, single phase
Voltage
48VDC [24 VDC, 150W (QTY 2)]
Wattage
300W (total)
Current Capacity
13.0A (total)
Power Supply (BUC)
A/C Input Voltage
85-264 VAC, 47-63Hz, single phase (see ADE power below).
GPS (On Board)
Waterproof
IPX7
Operating Temperature
-30°C to +60°C
Storage Temperature
-40°C to +60°C
Humidity
Up to 95% non-condensing or a wet bulb temperature of +35°C
Altitude
-304m to 18,000m`
Vibration
IEC 68-2-64
Shock
50G Peak, 11ms
Connector
RJ11
Input Voltage
Min
4.75VDC
Typ
5.0VDC
Max
5.25VDC
NMEA output messages
GGA, GLL
Refresh Rate
1s
14-4
EAR Controlled - ECCN EAR99