7. GEAR RACK MOUNTING

7.1.

Release the motor reducer and take the leaf to complete 

opening;

7.2.

Fix to each gear rack element the   support pawls using the 

appropriate lock screws, taking care to place them in the upper 
part of the hole (Fig. 17);

7.3.

Lean the gear rack element   on the toothed pinion of the 

motor so that it results parallel to the ground slideway of the 
gate,   place it as shown in Fig.18 and electrically weld the central 
pawl B to the gate structure (Fig. 19). 
Manually move the gate until pawl C is placed in 
correspondence to the pinion, now fix it with electric welding. 
Repeat   the same procedure for pawl A after having placed it in 
correspondence to   the pinion;

7.4.

Make sure   that all the gear rack elements are perfectly 

aligned and placed correctly (teeth in phase). It’s suggested to 
place two aligned elements infront of a third one as shown in 
Fig.20;

7.5.

Repeat the above described operation for all the remaining 

gear rack elements   which have to be installed;

7.6.

To avoid that the door weights down on the pinion (Fig.21) 

lift up the whole rack about 0,06 in. 

Warning

: Keep a gap of about 0,02 in between pinion tooth and 

gear rack tooth;

7.7.

Make sure that the gear rack works at the center of the 

pinion along all rack elements, if necessary, adjust the

 

distance 

pieces length.

Closing limit switch

Opening limit switch

8. LIMIT SWITCH ADJUSTMENT

8.1. 

To set up and adjust the limit switches in opening, follow the 

instructions written here (Fig.22):
- Bring the gate in complete opening, 
- Place the limit switch plate on the gear rack to have the limit 
switch (lever in case of mechanical limit switch (Fig. 23); pointers 
placed in the higher part in case of inductive limit switch (Fig.24)) 
in correspondence with the X point which is 1,96 in. from the 
folded side of the plate (Fig.25) and fix it with the supplied screws 
(Fig.26).

8.2. 

To set up and adjust the limit switches in closing, follow the 

instructions written here (Fig.22):
- Bring the gate in complete closing, 
- Place the limit switch plate on the gear rack to have the limit 
switch in correspondence with the X point which is 1,96 in. from 
the folded side of the plate (Fig.25) and fix it with the supplied 
screws (Fig.26).

Cod. 67410022

REV 00 - 12/2013

®

International registered trademark n. 2.777.971

MECHANICAL INSTALLATION

7

Summary of Contents for LEPUS 1000

Page 1: ...MOTOR Cod 67410022 REV 00 12 2013 International registered trademark n 2 777 971 web site www sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 ...

Page 2: ...ng of external controls and devices serving as required protection against entrapment shall be provided with the operator when such controls are shipped with the operator Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where applicabl...

Page 3: ...eded by building structures natural landscaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more conta...

Page 4: ... The operator has a mechanical adjustable clutch which ensures the control of the gate pushing Moreover the electronic reversing device realized through an encoder makes the lepus motor reducer a safe and reliable operator allowing in a simple way to comply with the current norms in the countries where this product is set up 1 Adjustable Foundation plate 2 Anchor bolts 3 Angular cover 4 Pinion 5 L...

Page 5: ...RECAUTIONS WARNING Moving Gate Can Cause Serious Injury Or Death KEEP CLEAR Gate may move at any time without prior Warning Do not let children operate the gate or play in the gate area This entrance is for vehicle only Pedestrians must use separate entrance A N G R I W N A N G R I W N a s au v M n a e i C e t C g n o G y In O j D i r er h u t r s ou a S e E m E E K y a t AR t e L y P a a C v n e ...

Page 6: ...onsidering the mentioned measurements in Fig 13 6 2 Remove the closing loading oil cap red and substitute it with that supplied apart provided with the airhole black 4 MOUNTING PLATE INSTALLATION To install the mounting plate it is necessary to 4 1 Have a mounting plate manufactured to the dimensions shown in Fig 12 The plate will require to have concrete holding into which the foundation plate an...

Page 7: ...ghts down on the pinion Fig 21 lift up the whole rack about 0 06 in Warning Keep a gap of about 0 02 in between pinion tooth and gear rack tooth 7 7 Make sure that the gear rack works at the center of the pinion along all rack elements if necessary adjust the distance pieces length Closing limit switch Opening limit switch 8 LIMIT SWITCHADJUSTMENT 8 1 To set up and adjust the limit switches in ope...

Page 8: ...ive limit switch Place where the wheel mechanical limit switch or the arrow inductive limit switch must be 11 ASSEMBLING OF THE CHAIN SYSTEM The assembling of the main parts which include the whole chain automation is illustrated in Fig 29 In the pictures 30 and 31 it is possible to see the correct installation with opened and closed gate respectively notice the obliged run of the chain inside the...

Page 9: ...may derail from the pinion group or the motor reducer risks a greater effort not allowing the right operating of the system 11 3 Set up a fillet chain tensioner to the two extremities of the gate to regulate the tension of the chain Notice do this last operation with the engine completely unlocked through the special unlocking key Fig 34 Fig 32 1 77 in Fig 30 Fig 33 Fig 31 Fig 35 12 EXTERNAL RELEA...

Page 10: ...ABLE LAYOUT 1 LEPUS operator 2 Left photocell 3 Right photocell 4 Pneumatic safety edge 5 Key switch 6 Flashing warning lamp 7 Radio receiver 8 Warning notice 9 Electronic control unit or j 10 Differential switch unction box Cod 67410022 REV 00 12 2013 International registered trademark n 2 777 971 MECHANICAL INSTALLATION 10 ...

Page 11: ...Open the lock cover insert the key and rotate it 90 clockwise Fig 39 Pull the release lever until it stops about 90 approximately Fig 40 Note when you pull the release lever the electronic control unit receives a stop impulse thanks to a micro switch placed inside 15 2 In order to relock do as follows Push the release lever to complete closing Rotate the key counter clockwise and extract it Close ...

Page 12: ...rs 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing assembling and workmanship defects No warranty will be...

Reviews: