0,06 in.
Fig. 21
Fig. 17
Fig. 18
A
B
C
Fig. 19
Fig. 20
Fig. 22
7. GEAR RACK MOUNTING
7.1.
Release the motor reducer and take the leaf to complete
opening;
7.2.
Fix to each gear rack element the support pawls using the
appropriate lock screws, taking care to place them in the upper
part of the hole (Fig. 17);
7.3.
Lean the gear rack element on the toothed pinion of the
motor so that it results parallel to the ground slideway of the
gate, place it as shown in Fig.18 and electrically weld the central
pawl B to the gate structure (Fig. 19).
Manually move the gate until pawl C is placed in
correspondence to the pinion, now fix it with electric welding.
Repeat the same procedure for pawl A after having placed it in
correspondence to the pinion;
7.4.
Make sure that all the gear rack elements are perfectly
aligned and placed correctly (teeth in phase). It’s suggested to
place two aligned elements infront of a third one as shown in
Fig.20;
7.5.
Repeat the above described operation for all the remaining
gear rack elements which have to be installed;
7.6.
To avoid that the door weights down on the pinion (Fig.21)
lift up the whole rack about 0,06 in.
Warning
: Keep a gap of about 0,02 in between pinion tooth and
gear rack tooth;
7.7.
Make sure that the gear rack works at the center of the
pinion along all rack elements, if necessary, adjust the
distance
pieces length.
Closing limit switch
Opening limit switch
8. LIMIT SWITCH ADJUSTMENT
8.1.
To set up and adjust the limit switches in opening, follow the
instructions written here (Fig.22):
- Bring the gate in complete opening,
- Place the limit switch plate on the gear rack to have the limit
switch (lever in case of mechanical limit switch (Fig. 23); pointers
placed in the higher part in case of inductive limit switch (Fig.24))
in correspondence with the X point which is 1,96 in. from the
folded side of the plate (Fig.25) and fix it with the supplied screws
(Fig.26).
8.2.
To set up and adjust the limit switches in closing, follow the
instructions written here (Fig.22):
- Bring the gate in complete closing,
- Place the limit switch plate on the gear rack to have the limit
switch in correspondence with the X point which is 1,96 in. from
the folded side of the plate (Fig.25) and fix it with the supplied
screws (Fig.26).
Cod. 67410022
REV 00 - 12/2013
®
International registered trademark n. 2.777.971
MECHANICAL INSTALLATION
7