13) Standard installation
In Fig.17 you find the necessary wiring for the barrier installation.
The two numbers placed next to the electric cables show their quantity and section.
Legend:
1) Electronic control unit
2) Photocell (receiver)
3) Photocell (transmitter)
4) Key switch
5) Radio receiver
6) Warning light
7) Push button board
8) Main switch
Fig.17
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
2x AWG 16 min
2x AWG 16 min
2x AWG 16 min
4x AWG 16 min
3x AWG 14 min
3x AWG 16 min