13) Standard installation 

In Fig.17 you find the necessary wiring for the barrier installation.
The two numbers placed next to the electric cables show their quantity and section.

Legend: 

1) Electronic control unit
2) Photocell (receiver)
3) Photocell (transmitter) 
4) Key switch
5) Radio receiver
6) Warning light
7) Push button board
8) Main switch

Fig.17

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

2x AWG 16 min

2x AWG 16 min

2x AWG 16 min

4x AWG 16 min

3x AWG 14 min

3x AWG 16 min

14) Accessories

 for 

VELA INDUSTRIAL

PHOTOCELLS

KEY SWITCH  

WARNING LAMP

SKIRT (ONLY ON SIDE BEAM)

FIXED FORK 

SUPPORT 

ADJUSTABLE 

FORK SUPPORT 

FEXLIBLE FORK 

SUPPORT

COUNTER PLATE 

FOR FORK SUPPORT

LIMIT SWITCH KIT

117 (Vela Ind. Series) 

International registered trademark n. 2.777.971

SEA USA Inc.
10850 N.W. 21st unit 160 DORAL MIAMI  
Florida (FL) 33172

Phone:++1-305.594.1151 
Fax: ++1-305.594.7325
Toll Free: 800.689.4716

67410268

13

Rev. 01 - 11/2010

Summary of Contents for VELA INDUSTRIAL

Page 1: ...7 971 web site www sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 VELA INDUSTRIAL Rev 01 11 2010 117 Vela Ind Series 67410268 ...

Page 2: ...ns from the control panel s to the operator s must be made in a waterproof junction box The system requires a separate power supply circuit Check that the main power supply circuit breakers are separated intended solely for this equipment and rated for 15AMPS Visually check that the circuit breakers are in OFF position and mark the circuit breakers USED prior to installation Permanent wiring must ...

Page 3: ...opping the gate properly all the pinch points and potential entrapment areas are reduced Check and test all reversing devices The installer should instruct user on the operator system s proper operation They should together review the basic functions of the reversing devices and how to periodically test them Reversing devices include one or more of the followings reversing loops photocells reversi...

Page 4: ...tomation consists of The cataphoresis and epoxy treated dust painted steel sheet casing protects all mechanical and electric devices from atmospheric agents On request it is also possible to receive the casing in stainless steel The balancing spring is delivered according to the beam length inside the beam kit See spring tab Electronic control unit for 230 version advanced device which allows the ...

Page 5: ...y of use is valid only for the first hour at 68 F room temperature Nota2 For a frequency of more than 60 it is recommended to use the mechanical and electronic limit switch kit for a best duration in time Fig 1 16 8 44 6 3 37 Rectangular beam Barrier Length 17 feet 20 feet 23 feet 25 feet D Spring 0 41 in 0 43 in 0 45 in 0 49 in Fexlible support yes yes yes yes B light Beam Barrier Length D Spring...

Page 6: ...ng this operation release the as shown in Fig 18 operator Once exchanged the piston tighten its fixation screw and lubricate with grease Use DIN 51502 KP2 N 20 K 2 K 20 grease Spring support Spring tensioning bolt N B The operator comes as shown in Fig 1 Closing on the right hand side Fig 3 Fig 4 A 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 1...

Page 7: ... plate as in Fig 6 Level the plate with care The plate has got a central hole for electric wiring so before filling the hole with concrete put an elettric wire sheathing on the hole Concrete Fondation plate to be levelled Wire sheathing Clamps 60 Fig 6 16 31 5 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1...

Page 8: ... Tighten the column to the foundation plate screwing the provided nuts and bolts with care Fixing nuts bolts Hole for wire sheathing Fig 8 5 Mounting of the central beam with fork Fig 8 Beam Nuts and bolts for beam fixing Fig 7 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 ...

Page 9: ...Fig 9 Fig 9 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 67410268 9 Rev 01 11 2010 ...

Page 10: ...d only on lateral mounted beams Fig 11 Fig 10 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 67410268 10 Rev 01 11 2010 ...

Page 11: ...ocked NOTE For the correct balancing of the beam it is recommended to unhook the piston from the balance wheel extracting the pivot as in fig 4 Spring bolt locknut Spring tension adjusting bolt Fig 13 Unscrew breather cap Pressure adjusting valves 10 Force adjustment If necessary the piston force can be adjusted by the two adjusting screws grey and yellow placed on the front lower place of the Hyd...

Page 12: ... must be executed only if at the end stroke the beam is not in perfectly horizontal position in closing or in perfectly vertical position in opening Unlock the actuator through the release screw so that the beam opens and closes manually Release the end stroke screws unscrewing the lock nuts on the limit switch Fig 14 Screw or unscrew the end stroke screws so that the beam stays in perfectly verti...

Page 13: ...1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 2x AWG 16 min 2x AWG 16 min 2x AWG 16 min 4x AWG 16 min 3x AWG 14 min 3x AWG 16 min 14 Accessories for VELA INDUSTRIAL PHOTOCELLS KEY SWITCH WARNING LAMP SKIRT ONLY ON SIDE BEAM FIXED FORK SUPPORT ADJUSTABLE FORK SUPPORT FEXLIBLE FORK SUPPORT COUNTER PLATE FOR FORK SUPPORT LIMIT SWITCH KIT 117 Vela Ind Series International registered trademark n 2 777 971 SEA USA In...

Page 14: ... as follows Open the door with the delivered special key Turn about 90 into anti clockwise direction the release srew placed on the hydraulic unit Move the beam with the hand To re lock operate as follows Turn about 90 into clockwise direction the release screw placed on the hydraulic unit Close the door Hydraulic pump manual release Release Lock Verify the efficiency of the limit switches micro s...

Page 15: ...date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing assembling and workmanship defects No warranty will be recognized for damages due to ...

Page 16: ...w sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 777 971 ...

Reviews: