8.5

 

Control via application  SeaControl for OS android 

For control and monitoring of 

GSM-R5-Tx 

 

it’s

 possible to use application for device 

with OS Android, which is available for FREE. In your smartphone start Google Play and 

search  for  „

SeaControl

.  Application  communicates  to 

GSM-R5-Tx 

  with  SMS 

messages. Application control is intuitive - see enclosed pictures. 

 

Switch  between  each  device  by  swiping 
left or right. 
Pulse settings. 
Reset settings 
Temperature  control  setting,  for  some 

time interval 
In  history,  there  are  always  stored  two 

previous values. 
 

pulse length settings:   

 

setting temperature to control: 

 
 

9.

 

Data logger 

GSM-R5-Tx 

provides saving(logging) of detailed information about activity of the 

device. Interval of saving is changed through 

SeaConfigurator

. Saved log provides 

reverse  analysis  of  device  activity. 

Type of logged information are set by 
user  during  configuration  of 

GSM-

R5-Tx

.  It’s  possible  to  save 

information  about  state  changes  of 

each  inputs  and  outputs,  incoming 
outgoing  SMS.  Format  of  log  file  is 
.csv  (=  Comma  Separated  Values).  Name  of  the  file  is  same  as  the  day  it  was 

created(datum.csv). 
Saved logs are of two types: periodic and state-change.

  

 

 

 

 

*1) 

type (type2) 

- Types of records 

  

1 (period)  - regular period write 

 

2 (event)  - record caused by digital input or output state change 

 

3 (insms)  - received SMS 

 

4 (outsms) - sent SMS 

 

5 (incall)  - incoming telephone call 

 

6 (outcall)  - outgoing telephone call 

 

7 (debug)  - debug information 

 

8 (talk) 

- sound playback (not used) 

 

9 (fault)  - error 

 

32(fw)       - firmware upload 

 

*3)

 A1: 

 

O    … disconnected; 

 

 

Z     … Short circuit; 

 

 

?     … unknown;

 

 

[°C] ...

 

*2)

 Y.cmd: 

 

,R22.6/28.0  

R means regulation; current temperature is 22,6°C

 

 

 

 

 

regulated temperature is 28,0°C

 

 

 

 

- P is pulse 

 

 

 

- Q is reset 

 

 

10.

 

Warranty 

General 

warranty period is 24 months

 after purchase, when eventual malfunction 

device will be repaired free of charge in SEA spol. s r.o. while shipping to SEA is paid by 

customer and SEA pays for shipping back to customer. 
The warranty does not cover any damage caused by wrong use which does not comply 

the  technical  specifications  and  user  instructions  and  any  accidental 

damage (e.g. by water, lightening etc.). 
SEA spol. s r.o. has NO RESPONSIBILITY for any damage, lost, costs and 

any other problems direct or inducted, caused by device malfunction from 
any reason. 
In case of incompleteness or any damage in the packaging it is necessary 

to inform SEA spol. s r.o. immediately (within five days). 
 

 

CE Declaration of conformity 

in accordance with the Radio and Telecommunications Terminal Equipment Directive 1999/5/EC (R&TTE) and Directive 

2011/65/EU (ROHS). 

We 

SEA, spol. s 

r.o., Dolnoměcholupská 21, CZ 102 00 Praha 10,

 Czech Republic, 

ID

: 47117931 (

manufacturer

)

 

declare under our sole responsibility, that  product  

GSM RELE5 TEMP 

type   

GSM-R5-T 

is in conformity with 

the following standards:

 

health and safety: 

EN 60 950-1:2005+A1:2009 EN 60 950-1:2006+A11:2009+A1:2010+A12:2011 

EMC: 

 

ETSI EN 301 489-1 

ETSI EN 301 489-7 v1.3.1 

radio frequency: 

EN 301 511 v 9.0.2 

 

The last two digits of year in which the CE marking was affixed:

 

     17 

  

Place of issue: 

Praha

 

Name: 

Ing. Vladimír Rosůlek

 

Date of issue: 

9.1.2017 

Grade: 

director 

 

 

Type 

Description 

Example 

Time Local 

Local date and time 

2015-04-01 15:32:14 

type 

*1)

 

Type of saved log (number)

 

type2 

Type of saved log (word)

 

period 

phone/ 
event 

Telephone number / Event 

+420123456789 

text/ action 

Text of SMS message / Action 

GSM-R5-Tx: Input turned 
ON. 

A1[°C] 

*3)

 

State of analog input A1 

22,6 

Y2 

State of output Y2 

Y2.cmd 

*2)

 

Output Y2 is regulated to value 28,0 

(current value is 22,6) 

,R22.6/28.0 

X3 

State of input X3 

AP 

Analog input "power" [V] 

14,4 

PWW 

Digital input "power" 

GSM.cell 

Information about BTS 

23002F,0404,047A_006E 

GSM.sig 

GSM signal strenght [%] 

35 