background image

GSM-R5-Tx_User_Manual_EN_v1-16.docx 

Page # 6 of 

6

 

15.

 

Frequently Asked Questions (FAQ)  

What is necessary to use the GSM-R2-T: 

 

Good quality GSM signal in the place where GSM-R2-T is used (at least 2 bars on your mobile phone) 

 

Sufficient credit (in case a pre-paid SIM card is used)  

 

No phone call redirection 

 

The user has to know to operate his mobile phone (PIN usage deactivation, Phonebook contact changing) 
 

Problem description 

Possible cause 

Solution 

Blue LED diode GSM does not start  

blinking once per 3 seconds during 3 
minutes after power on of GSM-R2-T 

No SIM card inserted 

or 

SIM card is not functional 
 

 
 

 

New SIM card which was 
not activated yet 

 
Low credit on a pre-paid 

SIM card 

 
 

 
 

 

 
Low quality GSM signal 

 

Test the SIM card in your mobile phone. Try to make a call and receive a call from another mobile 

phone. Try to send a receive SMS message.  

Switch off using PIN on a SIM card. Cancel all call redirection for a SIM card. (Ask your mobile operator 
for help if necessary) 

 
New SIM card has to be activated. (Ask your mobile operator for help if necessary) 

 

Check credit on a prepaid SIM card 
 

 
Tip: in the Czech Republic the codes are: 

*22#   Vodafone (Vodafone card) 

*101#  T-Mobile (Twist) 
*104*#  O2 (GO) 

 
 

 

Test the GSM signal level with your mobile phone in the same location where you will use the GSM 

RELAY 2. For a test use a SIM card from GSM RELAY 2 (it’s important to test GSM signal of the same 

GSM operator). The mobile phone should show the signal level at least 2 bars. 

The pulse on an output is not 
generated based on an incoming call 

(e. g. for a gate opening) 

Phone calls are redirected 
for the SIM card which is  

inserted in GSM-R2-T 

Cancel all phone calls redirection for the SIM card which is inserted into GSM RELAY. 

The “temperature regulation” 

function of GSM-R2-T was 

deactivated  

GSM-R2-T was 

deactivated by incoming 
phone call by master 

Change the parameter xRemCall 

= 0 on SIM card to deactivate the function “pulse by ringing”. Then 

activate the “temperature regulation” function again by SMS. E.g. “1234 TEMP25”.

 

 

The temperature from an external 
temperature sensor is wrong 

Too long lines to an 

external temperature 
sensor 

The accuracy of temperature depends on a line length to an external temperature sensor (16 Ohms 

means 1°C). Use thicker wires to temperature sensor.

 

Some parameters are missing on the 

SIM card 

The phone book on a SIM 

card is full. (There is no 
place on a SIM card for 
parameters) 

Delete some of contacts in the phone book on a SIM card (minimum is 60 free contacts). 

 

16.

 

A list of the most frequently used parameters 

See 

www.seapraha.cz

 

, find the device’s website and

 download the file "Complete list of commands". 

 

 
 

 
 

Reviews: