background image

GENERAL SAFETY REGULATIONS FOR THE INSTALLER

• The installer has to read and understand the functioning of this operator system, its safety features and knowing the manual function in case of emergency.
• Do not modify in any way the automated system’s components. SEA USA Inc. declines all liability concerning the automated system’s security and efficiency if 
the used components are not produced by SEA USA Inc. For maintenance, strictly use original SEA USA Inc. spare parts.
• The installer shall supply the user with all information concerning the proper operation of the product, the system’s manual functioning in case of emergency and 
shall hand over to the user the warnings handbook supplied with the product.
• SEA USA Inc. recommends the system to have reversing sensor (encoder) on the drive shaft of the motor. In case of swing/linear/in-ground hydraulic 
operators/barriers, SEA USA Inc. recommends to install the SAFETY GATE as an additional reversing sensor. Reversing devices are required to prevent the 
system from closing on vehicular traffic and/or help to prevent injuries to pedestrians.
• It is recommended to use indicator-lights as well as warning signs for every system. Both should be visible on each side of the gate and well fixed on the frame 
structure.
• Do not leave packing materials (plastic, polystyrene, etc.) within children’s reach, as they are potential sources of danger.
• For products having an emergency release, it is recommended to use it only when the gate/barrier is closed.
• Remove all locks connected to the gates before installing the operator.

• Locate the control button: (a) within sight of door, (b) at minimum height of 5 feet so that small children are not able to reach it, and (c) away from all moving parts 
of the door.
• Install entrapment Warning Label next to the control button in a prominent location. Attach marking next to the emegency release.
• Do not employ for any reason automatic closing devices (such as timer, loop sensors, or similar), and do not connect any other activation devices.

GENERAL SAFETY REGULATION FOR THE USER

• Sea strongly recommends to follow these instructions literally to prevent very serious damages to persons. This product was designed and built strictly for the 
use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a 
source of danger. SEA USA Inc. declines all liability caused by improper use or different use in respect to the intended one.
• Only qualified personnel can install, repair and periodically check this equipment.
• The User must not attempt to repair or to take direct action on the system and must solely contact qualified SEA personnel or SEA service centres. User can 
apply only the emergency manual function.
• The system has been designed for the control of vehicular traffic only. Pedestrians or bicycles must have a separate access opening.
• Do not allow children or adults to stay near the product while it is operating. The application cannot be used by children, by people with reduced physical, mental 
or sensorial capacity, or by people without experience or necessary training. Keep remote controls or other pulse generators away from children to prevent 
involuntary activation of the system.
• Transit through the leaves or barrier is allowed only when the gate/barrier is fully open. Operate system only if it is fully visible, and free of obstructions.
• For products having an emergency release use it only when the door/barrier is closed.

ELECTRICAL CONNECTIONS - SAFETY INSTRUCTIONS

• Disconnect the battery back up, if included, before disconnecting main power supply.
• Always disconnect power supply during installation or servicing of the product.
• All electrical connections from the control panel’s to the operator’s must be made in a waterproof junction box.
• The system requires a separate power supply circuit. Check that the main power supply circuit breakers are separated, intended solely for this equipment and 
rated for 15 AMPS. Visually check that the circuit breakers are in OFF position and mark the circuit breakers USED prior to installation.
• Permanent wiring must be used and installed to the operator as required by local electrical codes and It is recommended to do by a licensed electrician.
It is also recommended to check the local building code requirements before making any type of wiring to be sure that all wirings comply with them. Local building 
codes will take precedence. It is recommended to use different colours for all wirings’ codes.
• Distance for low voltage control wires, i.e., open input, single leaf, open input and stop input, can run up to 3000 feet with 18 AWG wire. Low voltage controls and 
communication wirings must all be separated by a minimum of 1 foot from high voltage power wiring and in a separate conduit.

GROUNDING

• Good grounding and proper surge suppression are an integral part of proper installation for all operator systems. One or all of the followings may require surge 
suppressors: high voltage power lines, low voltage power lines, telephone lines, data lines, low voltage control lines and loops. Quantity of surge suppression 
requires depends on susceptibility of the area to lightning and power surges. Good grounding is essential to realize maximum protection.
• If the circuit breaker box is located close to the gate/barrier operator system, for example, in a guardhouse, then the ground from that circuit can be used to 
ground the gate operator system. Eliminate all 90° bends in ground wires and keep a minimum distance of three feet between the surge suppressor and the 
equipment to protect.
• If the power source or circuit breaker box is not located close to the operator system, an Isolated Ground Zone (IGZ) must be created. An IGZ is an imaginary 
circle drawn around the operator system. An IGZ can also be created, if the circuit breaker box is located close to the operator system. The operator system not 
only includes the operator and control panel, but all accessories and devices associated with it at that controlled entry point. This includes loop detectors, card 
readers, digital entries, telephone entries, any device that has or requires grounding and all the surge suppressors. The ground bus is a common ground point 
called Single Point Ground (SPG). It is used to bond all the equipments and devices grounded in the IGZ together. The SPG is very important because it helps to 
eliminate different ground potentials that can be present on the equipment and that could cause damages even with surge suppressors.
• Do not use or connect the ground wire coming from the circuit breaker box. By using an Isolated Ground Zone, you have to separate the operator system from 
the house or building ground. This eliminates ground potentials. It is recommended the ground bus to be located in a separate NEMA type enclosure. All grounds 
will be tied to this ground bus.
• Equipment ground wire should be of minimum 12 AWG. The main ground wire from the bus bar to the ground rod should be an 8 or 6 AWG copper wire.
Ground rod should be minimum 10 feet in length, (length depends on local soil conditions).
• For more information, regarding good grounding practices check: National Electric Code art. 250; IEEE Emerald Book, standard 100; International Association 
of Electric Inspectors.

• Where possible, install the opener control 7 feet or more above the floor. For products having an emergency release, mount the emergency release 6 feet above 
the floor.

SEA USA Inc.
10850 N.W. 21st unit 160 DORAL MIAMI  
Florida (FL) 33172

Phone:++1-305.594.1151 
Fax: ++1-305.594.7325
Toll Free: 800.689.4716

®

International registered trademark n. 2.777.971

Storm 24V

Rev. 00 - 11.2010

Code 67411125

2

Summary of Contents for STORM 24V

Page 1: ...red trademark n 2 777 971 web site www sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 Rev 00 11 2010 Code 67411125 ...

Page 2: ...tions from the control panel s to the operator s must be made in a waterproof junction box The system requires a separate power supply circuit Check that the main power supply circuit breakers are separated intended solely for this equipment and rated for 15AMPS Visually check that the circuit breakers are in OFF position and mark the circuit breakers USED prior to installation Permanent wiring mu...

Page 3: ... stopping the gate properly all the pinch points and potential entrapment areas are reduced Check and test all reversing devices The installer should instruct user on the operator system s proper operation They should together review the basic functions of the reversing devices and how to periodically test them Reversing devices include one or more of the followings reversing loops photocells reve...

Page 4: ...consists of The cataphoresis and epoxy treated dust painted steel sheet casing protects all mechanical and electric devices from atmospheric agents On request it is also possible to receive the casing in stainless steel The balancing spring is delivered according to the beam length inside the beam kit See spring tab GATE 1 electronic control unit for 230 version and USER 1 24V for 24V version adva...

Page 5: ...n the desired side it is possible to invert it following the instructions Fig 1 Note The frequency of use is valid only for the first hour at 20 C room temperature Rectangular beam Barrier Length 16 40 feet 19 68 22 96 24 60 D Spring 0 41 in 0 43 0 45 0 49 Fexlible support yes yes yes yes Linear beam Barrier Length D Spring Fexlible support yes yes yes Type of skirt 14 76 feet 18 04 21 32 Barrier ...

Page 6: ...ig 4 and 5 N B Before executing this operation release the motor reducer as shown in Fig 19 Once exchanged the connecting rod tighten its fixation screw and lubricate with grease Use DIN 51502 KP2 N 20 K 2 K 20 grease Tighten at Max 50 Nm Spring support Spring tensioning bolt Fig 3 Mi 39 n 0 in Min 39 in 0 Fig 6 Fig 4 Fig 5 Connecting rod Connecting rod SEA USA Inc 10850 N W 21st unit 160 DORAL MI...

Page 7: ...tion plate as in Fig 8 Level the plate with care The plate has got a central hole for electric wiring so before filling the hole with concrete put an elettric wire sheathing on the hole Concrete Fondation plate to be levelled Wire sheathing Clamps 60 Fig 8 15 74 31 49 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 Int...

Page 8: ...n Tighten the column to the foundation plate screwing the provided nuts and bolts with care Fixing nuts bolts Hole for wire sheathing Fig 9 Fig 10 5 Mounting of the central beam with fork Fig 10 Beam Nuts and bolts for beam fixing SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 77...

Page 9: ...g 11 Fig 11 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 777 971 Storm 24V Rev 00 11 2010 Code 67411125 9 ...

Page 10: ...eam at 45 Fig 14 After balancing fix the spring adjusting bolt locknut with the bolt and block the motor reducer 9 Barrier power supply Now it is possible to power supply the barrier Place the beam at approx 45 and execute the balancing with the nuts of Fig 14 To obtain a correct balancing the beam must be on 45 and the operator must be unlocked SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Flor...

Page 11: ...rews so that the beam stays in perfectly vertical position in opening and in perfectly horizontal position in closing Fig 15 After levelling fix the end stroke by tightening the lock nuts on the limit switch and block the actuator Spring tension adjusting bolt Spring bolt locknut 11 Levelling of the central beam with fork First extract the screws B than the screws C Fig 16 Continue as described in...

Page 12: ... button board 8 Differential switch Fig 18 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 2x1 2x1 2x1 1XRG58 4x1 3x1 5 3x1 PHOTOCELLS SKIRT ONLY ON SIDE BEAM COUNTER PLATE FOR FORK SUPPORT KEY SWITCH WARNING LAMP 13 Accessories for STORM FIXED FORK SUPPORT ADJUSTABLE FORK SUPPORT FEXLIBLE SUPPORT ONLY BEAM SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 To...

Page 13: ...CE Check the functionality of the release Annually Lubricate all moving parts Annually Check the efficiency of the spring balancing Annually Check the beam fixing screws the balance and the casing Annually Check the integrity of the connexion cables Annually All above mentioned operations must be executed exclusively by authorized installers SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida ...

Page 14: ...nths warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing assembling and workmanship defects No warranty will be recogni...

Page 15: ......

Page 16: ...w sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 777 971 ...

Reviews: