| P
age 37
|
SEABOB
Operation
Manual
|
5
5.4.4 Display (operation display)
The graphic display is divided into three fields. During op-
eration of the craft, the following information is shown
in the main menu:
Left field:
On the top left-hand part of the display, additional sym-
bols may appear. Below is a list of these symbols and
their descriptions:
Warning symbol
• Accumulator charge state low, emergency mode (ac-
cumulator symbol flashing)
➞
Charge accumulator
box!
• Maximum diving depth exceeded (diving depth dis-
play flashing)
➞
Motor stops
• When timer has been activated: remaining operating
time is less than 25 % of the entire operating time
(timer display flashing)
• Accumulator temperature warning (accumulator sym-
bol and temperature display flashing)
➞
Power is lim-
ited to 30 %
Stop symbol
• SEABOB not ready for operation
• Accumulator discharged
➞
Charge accumulator box!
• When timer has been activated: operating time
elapsed
• Maximum accumulator temperature exceeded (ac-
cumulator symbol and temperature display flashing)
➞
Motor stops
Workshop symbol
• Motor defect
• Accumulator defect
• System defect (such as water leakage in accumulator
box or electronic system)
➞
Contact manufacturer or specialist dealer!
Charge symbols (in charge display)
• Partial charging to accumulator charge state for
air transport / storage
• Full charging to full accumulator charge state
for operation
Aircraft symbol (in charge display)
• Charge state for air transport / storage reached
Sun symbol (in "settings" menu)
• Mode for setting the display brightness
The current water temperature (in °C) is shown under the
optionally displayed symbols.
Below, the current diving depth (in m) is displayed.
Note
: If you activate the Timer to limit the operating time,
the remaining operating time (in hrs:min) is displayed in-
stead of the water temperature (Timer is activated via
the menu using the Owner-PIN; Timer is activated at an
operating time > "0:00").
Left
field
Middle
field
Right
field
Power (in % of maximum power)
Water
temperature
Diving depth
Accumulator
charge state
Remaining
operating time
(in hrs:min)