STS11 Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (CONTINUED)
52
Installer
Setup
Number
Installer
Setup
Name
Settings Notes
Initial
Setting
Record
0690
Temperature
Control in Cool
1- Highest energy savings.
2- Moderate energy savings.
3- Least energy savings.
Default setting is # 1
0700
Temperature
Display Offset
-3°F (-1.5°C)
-2°F (-1°C)
-1°F (-.5°C)
0°F (0°C)(no difference in displayed
temperature and actual room
temperature )
1°F (.5°C)
2°F (1°C)
3°F (1.5°C)
Factory Accuracy
±
1°F
Purpose of Offset:
1-Components may change value
overtime or compensate for internal
component values changes.
2-Compensate for air flow conditions
Use a reliable independent
thermometer and record room
temperature. Use offset to have
thermostat temperature match
independent reading
0710
Reset
Thermostat
0-no thermostat reset.
1-resets all Installer Setup Options to
default values and resets schedule to
default setting.
Only calendar settings and time are
retained.
STS11 Touchscreen Programmable Thermostat
INSTALLER SYSTEM TEST
Use the Installer System Test to test the W Y and L terminals.
CAUTION
Equipment Damage Hazard.
Minimum compressor off time is bypassed during
Installer System Test
Avoid cycling compressor quickly.
53
How to Use the Installer System Test
The Installer Test is part of the Installer Setup Menu.
1. Enter the Installer System Test by entering the Installer Setup.
2.
Note that the test appears at the end of the Installer Setup Numbers.
3.
See Fig. 25. to review how the thermostat buttons are used during the Installer System
Test. See table 4 (pg 55) for available Installer System Tests.