background image

10

English

Unscrew the Torch bottom whilst holding on the handle and extract it from the
lamp body while holding the latter vertical with the optics downward.
Connect the charger to mains and connect it through the appropriate jack to the
outlet located beside the lamp holder
Check that the green led lights up when the charger is connected to mains.
The charging time from flat is shown in the table.
As soon as the needed voltage has been reached, the automatic charger cuts
off the supply and remains in standby mode until disconnected from mains (see
paragraph “Technical Specifications of the Battery Charger”).
When the Torch has been recharged, close it after previously cleaning and
lubricating the O-Rings and relevant seats.
In case of prolonged non-use, carry out a complete discharging-charging cycle
every three months (discharge with submerged Torch).
All Torches are equipped with a battery protection electronic circuit, which
disconnects the feed current when the voltage drops under a specified threshold
and prevents possible polarity inversion, which would cause irreparable damage
to the batteries.
However, avoid leaving the torch under charge for long periods of time.

W A R N I N G

never switch on the torch outside the water
never unscrew the torch head or bottom during diving or if wet

C H E C K S   B E F O R E   D I V I N G

Check for perfect seal of the body.
When in water, check, by immersing the torch, that there is no continuous
discharge of air bubbles from the case.

F L O O D I N G

In case of flooding, open the torch and immediately rinse inner parts in fresh water,
then wipe with a cloth and with an air source paying particular care to the electronic
circuit. Remove the oxide, if any, formed on metal parts and immediately proceed
to recharge.
If the quantity of water leaked inside the torch is considerable and if it has remained
there for a long time, it is recommended to cut and remove the plastic protection film
and then proceed as described above.

L I M I T S   O F   U S E

The maximum operating depth is 100 m.
Owing to the high temperatures reached by the lamp, it is recommended to use
the torch ONLY underwater.

Summary of Contents for SeaRay Plus Series

Page 1: ...illuminatori SeaRay Plus SeaRay Plus torch w w w s e a c s u b c o m ...

Page 2: ...s SeaRay Plus torches instruction manual Manuel d instructions de l eclairages sous marins SeaRay Plus Bedienungsanleitung Leuchten SeaRay Plus Manual de instrucciones lámparas SeaRay Plus Pagina 3 Page 8 Page 13 Seite 18 Página 23 N I M H B A T T E R I E S P A C K ...

Page 3: ...ger and batteries An overpressure valve calibrated to 1 bar is also provided to prevent possible burst of the bulb in case of accidental formation of gas The main body is in anticorodal anodised aluminium while the parabolas used are in aluminium with a new satin finish providing a light beam with the following characteristics strongly focused in the center but with a large beam width The Xenophot...

Page 4: ...omatic Charging Time 5 h 5 h Burn Time in minutes With 20 bulb up to 50 min With 100 bulb up to 95 min With 50 bulb up to 43 min With 35 bulb up to 59 min With 20 bulb up to 100 min Maximum Depth 100 metri 100 metri Parabola Material Aluminium Aluminium Portlight 6mm Tempered Glass 6mm Tempered Glass O Ring NBR NBR Weight in air 713 gr 1077 gr Weight in water 405 gr 649 gr Length 181 mm 257 mm B A...

Page 5: ...when the voltage drops under a specified threshold and prevents possible polarity inversion which would cause irreparable damage to the batteries However avoid leaving the torch under charge for long periods of time W A R N I N G never switch on the torch outside the water never unscrew the torch head or bottom during diving or if wet C H E C K S B E F O R E D I V I N G Check for perfect seal of t...

Page 6: ...recharging your torch please check the correspondence between battery charger and torch C A U T I O N NON observance of these instructions may cause irreparable damage to the battery pack U S E Check that the torch switch is in OFF position Supply with battery charger mod M706C supply the battery charger with 220V The green LED lights up If you connect the plug with the battery of the torch the re...

Page 7: ...standard consumption parts such as O Rings batteries bulbs glass etc This warranty does not cover damage resulting from mechanical shocks prolonged use in chlorinated or polluted water prolonged exposure to strong heat sources exceeding 70 C The warranty is cancelled if the equipment has been improperly used not following the instructions for use the owner has made modifications or tampered and ha...

Page 8: ...Seac Diving Pro s r l Via Domenico Norero 29 16040 S Colombano Certenoli Genova Italy Telefono 39 0185 356 301 r a Fax 39 0185 356 300 www seacsub com seacsub seacsub com ...