SC4x0 Technical manual
Page 15 of 34
SeaCom
Rev
2.00
5.3 Monitor input
This item is mainly used for testing hardware. It will show input values from PTT, HOOK & sensors.
Temperature: -20 - +90°
Displays actual board temperature.
Dimmer input: 0 – 100%
Displays actual external dimmer input level.
Light sensor:
0 – 100%
Displays actual light sensor level.
If signal from headset PTT or handset hook switch is detected, display will show coherent text.
5.4 Set parameter xx
This item is used to adjust all hidden parameters not accessible from the main menu system. Each
parameter is given as id number. The number can be found in the section ‘Parameter list for hidden
menu’.
First key the number of the parameter to change. When pressing ‘M’, display will show current value
for that parameter. If the value is not to be changed, just press ‘M’ to return. If a change is requested,
key in a new value using 0-9. If range is 0-9, only one digit can be entered. To enter the new value,
press ‘M’.
If the new value is out of range, data will be replaced by high or low boundary value.
Depending on the type of data, ‘.’ Or ‘-‘ can be entered using the F-keys. F3 will erase last entered
digit.
5.5 Recall factory
This function will clear all user settings and restore them to factory values.
Use this function if there is any doubt re. current settings, to set all parameters.
From software 090928, all new parameters will automatically preset to factory values on first power up
after software update.
When updating software, it is always a god idea to note deviations from factory settings before
recalling.
Especially if adapted for special use.
NOTE: memory & speed dial data will NOT be erased by this function.
5.6 Erase eeprom
This function will erase all settings, all speed dial data, all mem dial data and call logs and cause the
unit to reload factory settings to all parameters on first power up
5.7 Reset
This function will cause the device to restart as if power was recycled. Use this function to read current
software rev., hardware rev or software id from the power up menu.
5.8 Sys test
This function will engage a small test sequence to test alarm relay and display.
Will revert to idle after 10 sec.