52
JDL V1.0 8 2022
Coin Changer Errors
Error Message
Description
Possible Solutions
Coin Mech Comm
VMC does not have communica-
tion with the coin changer.
Check MDB Harness to changer. Check for
power on changer. See changer service
manual.
Coin Mech Tube Sns
The coin changer has reported a
tube sensor error.
See changer service manual.
Coin Mech Inlet
The coin changer has reported an
acceptor blockage.
Check changer tubes. See changer service
manual.
Coin Mech Tube Jam
The coin changer has reported a
tube payout error.
Check changer tubes. See changer service
manual.
Coin Mech ROM
The coin changer has reported a
program memory error.
See changer service manual.
Coin Mech Excess Esc
The coin changer has reported
that a large number of coin escrow
requests have occurred.
Check changer escrow lever position.
Coin Mech Coin Jam
The coin changer has reported that
a coin is jammed in the coin path.
Check changer coin path. See changer ser-
vice manual.
Coin Mech Low Accept
The VMC has seen a low accep-
tance rate on coins.
Review inserted coins. See changer service
manual.
Coin Mech Accpt Disc
The coin changer has reported
that the coin validation acceptor is
disconnected.
Re-connect the coin changer’s acceptor. See
changer service manual.
Coin Mech Route Err
The coin changer reported that
a coin did not follow the correct
path.
Check changer coin path. See changer ser-
vice manual.
Bill Validator Errors
Error Message
Description
Possible Solutions
Bill Val Comm
VMC does not have communica-
tion with the bill validator.
Check MDB Harness to validator.
Check for power on validator.
Bill Val Stack Full
The bill validator has reported that
the stacker is full of bills.
Check bill stacker box for bills. See
validator service manual.
Bill Val Motor Err
The bill validator reports that a val-
idator motor error has occurred.
See validator service manual.
Bill Val Jam
The bill validator reports a bill is
stuck in the bill path.
Check validator bill path for bills.
See validator service manual.
Bill Val Stack Open
The bill validator is reporting a bill
box is open or not installed.
Check bill stacker box for open lid.
See validator service manual.
Bill Val Sensor Err
The bill validator reports a sensor
error.
See validator service manual.