background image

Rev. 2012.02.27 

10

 
To Change .. do the following: 
 
1. Press the Red Service Button till AS 

 

 

Displays AS-* 

 

where * is the current version # 

2. Press Button 1 (or 2) to increment/decrement Version # 

Displays AS.0?   where ? is version 1 to 6 

3. Press Button 3 to store Version Value 

 

 

Displays set 

4. Press Red Service Button or Reject to scroll to exit   

Displays 00.00 

 
 

 

Notes 

 

-

 

When setting up a Motor Version a default Timing value will be assigned automatically, (see default value). This may need 
to be changed (see timing value setting). 

-

 

The default motor version is Version 2. 

-

 

The VMC will return to Normal Mode (00.00) 60 seconds after the last button has been pressed unless the Red Service 
Button has been pressed or the reject is pressed. 

 

Timing Value

 

The timing value is a measure of time that allows the VMC to either ignore any signals from the motor until the time has expired, or 
if the time has expired without any signals. Depending on the Version, the timing Value has different characteristics. 
 
Generally speaking the timing value is set to the normal vend time. For example, if the vend normally takes 6 seconds to complete, 
then set the timing value to 6. This allows for the VMC to ‘expect’ a home signal at the required time and to ignore any spurious 
signals in the meantime. It also sets an appropriate delay after a ‘home’ should be expected, disabling power to the motor if this 
home wasn’t reached. In this case the motor is inhibited, the appropriate error code is set and the money entered is returned to the 
user. 
 
The Vend cycle is Voltage and Load dependent so an approximate setting of the timing value needs to be set. The vend cycle, is 
the time from motor start (when at home) to motor end (return to Home) in seconds. This translates directly to the timing value that 
re-conditions the value for correct operation. 

 

 

Operation 

 
1. Press the Red Service Button to scroll to   

 

 

Displays AS.— 

2. Press Button 1 (or 2) to increment/decrement Value  

 

Displays AS.**   where ** is value 01 to 99 

3. Press Button 4 to store Timing Value 

 

 

 

Displays set 

 

 Notes 

 

-

 

The current timing value is displayed whilst doing a test as Pl.**, where ** is current value 

-

 

The timing Value can be set from 00 to 99. 

-

 

For Version 1 Motors the default timing value is 7 

-

 

For Version 2 Motors the default timing value is 7 

-

 

The timing value reverts back to default every time a version change is set 

-

 

The timing value cannot be individually assigned and applies to all outputs when set. 

-

 

The VMC will return to Normal Mode (00.00) 60 seconds after the last button has been pressed unless the Red Service 
Button has been pressed or the reject is pressed. 

 

Negative Counter Sold Out Feature 

 

Negative Counter can only be set and calibrated for each selection by entering Service Code nc . Selection can be incremented or 
decremented from 1 to 5 using buttons 1 and 2 respectively and each shelf can be allocated a negative counter  from --.00 to --.99, 
where - - belongs to the shelf number. Negative counter value is incremented by button 3 and decremented by button 4. Each 
configuration can be saved by button no. 5. 

 

1.Operation  

 

1. Press the Red Service Button Repetitively till  LCD Displays:-  

nC .- - 

 
 

You are now in Negative Counter Setting Mode. 

 

2.Press Selection Button 1 to increment the  **.- -  Value i.e shelf selection no (** no. of shelf). 

 

                                                    

       

The LCD will now display the incremented selection no. 

 

Summary of Contents for SL5000

Page 1: ...Rev 2012 02 27 1 SL5000 Operator s Manual...

Page 2: ...n this process It is important that you keep the original packaging for your vending machine at least through the warranty period If your machine needs to be returned for repair you may have to purcha...

Page 3: ...M The delivery system of your SL5000 incorporates a Selection Pad an LCD Display and helix coils The customer inserts money into the coin slot and enters their selection on the Selection Pad the selec...

Page 4: ...0 seconds When the machine goes to sleep the following messages are displayed under set conditions When Awake When Asleep i 00 00 09 00 0 00 9 99 Decimal points always on ii 10 00 99 99 10 00 99 99 De...

Page 5: ...goes to Sleep 3 Service Mode can be exited by stepping through all the menu options using the Service Button or automatically if there is no activity for 30 seconds On Exit the software version numbe...

Page 6: ...ammed 4 Insert additional coins if required and repeat for other selections 5 Press Service Button to scroll to exit Prices may be set from 00 00 to 99 99 depending upon coin values The default price...

Page 7: ...nd Price Held until power removed Returned when ER pressed or held until power removed 05 Credit Vend Price Held for 60 seconds Returned when ER pressed or held for 60 seconds 06 None Free Vend Mode N...

Page 8: ...til Displays tE 2 Press Service Button to exit In Test Mode pressing a selection switch will operate the selected motor If a coin is inserted its value will be displayed for 1 second ALL MOTORS MODE 1...

Page 9: ...d Replace the battery 73 Battery nearly low Warning Replace recharge the battery soon Soft Errors unit will continue to operate though failed motors will show as Sold Out and be blocked from operation...

Page 10: ...t so an approximate setting of the timing value needs to be set The vend cycle is the time from motor start when at home to motor end return to Home in seconds This translates directly to the timing v...

Page 11: ...as been selected and the represents the current value of the Negative Counter that has been assigned to that shelf is displayed in scrolling mode from shelf 1 to 5 3 Sold out Feature After setting the...

Page 12: ...done to verify correct operation of the machine Further tests are done on Power Up Button Press Coin Insertion and entering exiting Service mode These tests will generate the relevant fault code as n...

Page 13: ...lection 2 for seconds till Displays set The machine will automatically exit from service mode and display Out Of Ord e r 3 Press Red Service Button to re enter Service Mode and re configure settings F...

Page 14: ...ce Exit Service Mode 62 Escrow Return Time out Check Escrow unit Activate Test Sequence Exit Service Mode 70 EEPROM Write Error Check Prices and Coin data 71 EEPROM Read Error Check Prices and Coin da...

Page 15: ...ution and reassemble COMMON QUESTIONS AND ANSWERS Q How High Can I set my Prices A Each selection can be priced individually up to 99 99 Q Can Customers reach down and help themselves to product A No...

Page 16: ...service repair alteration or disassembly has been performed Any defects caused by improper power source poor water quality or pressure an installed water filtration system not fully functioning abuse...

Reviews: