Rev.1.2 – 7.2018.EL950.1.3.1086C
50
Vend Sensor Errors
Error Message
Description
Possible Solutions
Optical Sensor Error
Not Applicable
NA
Coin Changer Errors
Error Message
Description
Possible Solutions
Coin Mech Comm
VMC does not have communication
with the coin changer.
Check MDB Harness to changer.
Check for power on changer. See
changer service manual.
Coin Mech Tube Sns
The coin changer has reported a tube
sensor error.
See changer service manual.
Coin Mech Inlet
The coin changer has reported an
acceptor blockage.
Check changer tubes. See
changer service manual.
Coin Mech Tube Jam
The coin changer has reported a tube
payout error.
Check changer tubes. See
changer service manual.
Coin Mech ROM
The coin changer has reported a
program memory error.
See changer service manual.
Coin Mech Excess Esc
The coin changer has reported that a
large number of coin escrow requests
have occurred.
Check changer escrow lever
position.
Coin Mech Coin Jam
The coin changer has reported that a
coin is jammed in the coin path.
Check changer coin path. See
changer service manual.
Coin Mech Low Accept
The VMC has seen a low acceptance
rate on coins.
Review inserted coins. See
changer service manual.
Coin Mech Accpt Disc
The coin changer has reported that
the coin validation acceptor is
disconnected.
Re-connect the coin changer’s
acceptor. See changer service
manual.
Coin Mech Route Err
The coin changer reported that a coin
did not follow the correct path.
Check changer coin path. See
changer service manual.
Bill Validator Errors
Error Message
Description
Possible Solutions
Bill Val Comm
VMC does not have communication
with the bill validator.
Check MDB Harness to validator.
Check for power on validator.
Bill Val Stack Full
The bill validator has reported that the
stacker is full of bills.
Check bill stacker box for bills. See
validator service manual.
Bill Val Motor Err
The bill validator reports that a
validator motor error has occurred.
See validator service manual.
Bill Val Jam
The bill validator reports a bill is stuck
in the bill path.
Check validator bill path for bills.
See validator service manual.
Bill Val Stack Open
The bill validator is reporting a bill box
is open or not installed.
Check bill stacker box for open lid.
See validator service manual.
Bill Val Sensor Err
The bill validator reports a sensor
error.
See validator service manual.
Card Reader 1 and 2 Errors
Error Message
Description
Possible Solutions