Cheetah 15K.5 SCSI Product Manual, Rev. H
47
9.0
Interface requirements
This section partially describes the interface requirements as implemented on the drives.
9.1
General description
This section describes in essentially general terms the interface requirements supported by the Cheetah 15K.5
SCSI. No attempt is made to describe all of the minute details of conditions and constraints that must be con-
sidered by designers when designing a system in which this family of drives can properly operate. Seagate
declares that the drives operate in accordance with the appropriate ANSI Standards referenced in various
places herein, with exceptions as noted herein or in the Seagate Parallel SCSI Interface Manual and the SCSI
Commands Reference Manual .
9.2
SCSI interface messages supported
Table 7 lists the messages supported by the Cheetah 15K.5 SCSI family drives.
Table 7:
SCSI messages supported by Cheetah 15K.5 SCSI family drives
Message name
Message code
Supported
(Y = yes)
(N = no)
Abort
06h
Y
Abort-tag
0Dh
Y
Bus device reset
0Ch
Y
Clear ACA
16h
N
Clear queue
0Eh
Y
Command complete
00h
Y
Continue I/O process
12h
N
Disconnect
04h
Y
Extended messages
01h[1]
Y
Identify
80h-FFh
Y
Ignore wide residue (two bytes)
23h
Y
Initiate recovery
0Fh
N
Initiator detected error
05h
Y
Linked command complete
0Ah
Y
Linked command complete with flag
0Bh
Y
Message parity error
09h
Y
Message reject
07h
Y
Modify data pointer
[1]
N
No operation
08h
Y
Parallel Protocol Request
[1] [2]
Y
Queue tag messages (two bytes)
ACA
24h
N
Head of queue tag
21h
Y
Summary of Contents for Cheetah ST3146855LW