Cheetah X15 36LP Product Manual, Rev. D
27
6.4
Environmental limits
Temperature and humidity values experienced by the drive must be such that condensation does not occur on
any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F
(14.8°C). Maximum wet bulb temperature is 82°F (28°C).
6.4.1
Temperature
a. Operating
With cooling designed to maintain the case temperatures, the drive meets all specifications over a 41°F to
131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 36°F (20°C)
per hour. The enclosure for the drive should be designed such that the temperatures are not exceeded. Air
flow may be needed to achieve these temperature values (see Section 8.3). Operation at case tempera-
tures above these values may adversely affect the drives ability to meet specifications.
The MTBF specification for the drive is based on operating in an environment that ensures that the case
temperatures are not exceeded. Occasional excursions to drive ambient temperatures of 122°F (50°C) or
41°F (5°C) may occur without impact to specified MTBF. Air flow may be needed to achieve these tempera-
tures. Continual or sustained operation at case temperatures above these values may degrade MTBF. The
maximum allowable continuous or sustained HDA case temperature for the rated MTBF is 122°F (50°C)
To confirm that the required cooling for the electronics and HDA is provided, place the drive in its final
mechanical configuration, perform random write/read operations. After the temperatures stabilize, measure
the HDA case temperature of the drive.
The maximum allowable HDA case temperature is 60°C. Operation of the drive at the maximum case tem-
perature is intended for short time periods only. Continuous operation at the elevated temperatures will
reduce product reliability.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This
specification assumes that the drive is packaged in the shipping container designed by Seagate for use
with drive.
Figure 10.
Locations of the HDA temperature check point
6.4.2
Relative humidity
The values below assume that no condensation on the drive occurs.
a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
b. Non-operating
5% to 95% non-condensing relative humidity.
6.4.3
Effective altitude (sea level)
a. Operating
–1,000 to +10,000 feet (–305 to +3,048 meters)
HDA Temperature
Check Point
.5"
2.0"
Summary of Contents for Cheetah X15 36LP ST318432LC
Page 2: ......
Page 6: ......
Page 10: ......
Page 12: ...2 Cheetah X15 36LP Product Manual Rev D ...
Page 22: ...12 Cheetah X15 36LP Product Manual Rev D ...
Page 30: ...20 Cheetah X15 36LP Product Manual Rev D ...
Page 39: ...Cheetah X15 36LP Product Manual Rev D 29 Figure 11 Recommended mounting Z Y X Z Y X ...
Page 52: ...42 Cheetah X15 36LP Product Manual Rev D ...
Page 86: ...76 Cheetah X15 36LP Product Manual Rev D ...
Page 92: ......
Page 93: ......