Hawk 2 (Wide bus) Family Install Guide, Rev. C
continued from previous page
Off On
Drive spindle does not start until Start Unit com-
mand received from host.
On Off
Spindle Startup is delayed by SCSI ID times 12
seconds after power is applied, i.e., drive 0
spindle starts immediately when DC power con-
nected, drive 1 starts after 12 second delay, drive
2 starts after 24 second delay, etc.
On On
Drive spindle starts when Start Unit command
received from host. Delayed start feature is over-
ridden and does not apply when ME jumper is
installed.
WP
On
Entire drive is write protected.
Off
Drive is not write protected. Default is no WP
jumper installed.
PE
On
Parity checking and parity error reporting by the
drive is enabled. Default is PE jumper installed.
Off
Drive does not report result of parity checking to
host.
TE
(Applies to "W" models only)
On
With the jumper installed, the optional on-board
(non-removable) terminator circuits are enabled
(connected to the I/O lines). Default is jumper
installed.
Off
Terminator circuits not connected to I/O lines.