Open the Drain Pan return valve, tank shut-off and flow valves, and
all
the Distribution Valves.
Turn Sealant Pump ON and let the water flush the system for 5
minutes.
Turn Sealant Pump OFF.
Remove and clean the screen in the Sealant Pump Filter by running
the screen under a faucet.
Reinstall screen ensuring that the bowl is screwed back on securely.
Remove the Sealant Tank dispose of the excess water.
Re-install Sealant Tank and re-fill with Sealant.
Purge all water from the system by closing the Sealant Tank Drain
Pan Return Valve(s).
With a hose connected to the System Drain Valve or a bucket under
the valve, run the pump until only sealant flows out of the Application
Tubs (repeat this step for 2
nd
tank, if equipped).
Ensure all valves are in their proper position for normal operation.
Turn the coater OFF.
Wipe up any water from Draw-Down Applicator and dry off all parts.