Problem / Symptom
Cause
Corrective Action
Pump impeller is locked or
broken
Check pump impeller for
obstruction and clear if
necessary
Replace pump
Pump is air locked
Bleed air from impeller
housing by opening the
drain valve on the pump
valve assembly.
Check all valves to make
sure one is not closed
thus preventing the pump
from priming
Poor pump pressure
Plumbing is obstructed
Check filters and valves
for obstructions and clear
if necessary
Check inlet at bottom of
sealant tank for
obstruction and clear if
necessary
Surface impressions
occur at the
Take-Up Roller
Insufficient drying
Reduce web speed
Increase heater panel
temperature
There is a leak at the
pump or inlet plumbing
Check for leaks and correct
them
Sealant tank is low and is
sucking air
Add more sealant to tank.
Sealant was frozen before
use
Remove old sealant and
refill with new
The sealant is
foaming
Pump has malfunctioned
Check for air trapped in the
pump and bleed by
opening the drain valve on
the pump valve assembly
Replace pump
Sealant in tank
develops a skin over
its surface
Sealant has been left
without agitation for too
long and has begun to dry
out
Pull skin off the top of the
sealant and add a small
amount of water (1 cup) and
allow the sealant to cycle
through the machine