Tank
5.3.1
Removing of waste water sensor
Picture 18: Waste water sensor
•
Open tank cover (02/102).
•
Disconnect the wire (13/107) of the waste water detector sensor
at the power electronic (04/108).
•
Remove the two sensor bolts (03/131).
•
Disconnect the sensor wires from the bolts.
•
Thread out the wires.