background image

                                                                                                                               

               

                                                                             

 

 

29 

 

         © Sealevel Systems, Inc. 

H1400811-8.4 Manual   |  SL9363  5/2022 

 

 

 

Passing RS485 loopback test - WinSSD in top image is transmitting port. 

11.

 

(RS485 only) Click on the ‘Stop’ button. Repeat steps 11 and 12 on the other port. 

 

 

Summary of Contents for H1400811-8.4R

Page 1: ...1 Sealevel Systems Inc H1400811 8 4 Manual SL9363 5 2022 HazPAC 10 8 4 Touchscreen Computer User Manual H1400811 8 4R ...

Page 2: ...ination and Pull up Pull down Resistors 15 Open Collector Outputs 16 SATA CFAST Type I II memory 19 Reset and Power buttons 20 HARDWARE INSTALLATION 21 SOFTWARE INSTALLATION 21 SEAMAX APPLICATION SUITE 21 MaxSSD Configuration Diagnostics Utility 22 Host PC Configuration Tab 22 Digital I O Tab 23 Troubleshooting SeaMAX 24 APPENDIX A TROUBLESHOOTING SERIAL COMMUNICATION ISSUES 25 Troubleshooting Ver...

Page 3: ... Inc H1400811 8 4 Manual SL9363 5 2022 Federal Communications Commission FCC Statement 33 EMC Directive Statement 33 China Compulsory Certification Statement 33 United Kingdom Conformity Assessed Statement 33 WARRANTY 35 ...

Page 4: ...nclosure suitable for mounting in hazardous locations see Installation Guide for details and is rated for a 30 C to 60 C operating temperature range The HazPAC10 8 4 power input accepts an absolute operating voltage range of 9 30VDC Features 8 4 800x600 400 nit TFT LCD with LED backlight Durable resistive 5 Wire touchscreen Intel Atom E3845 1 91GHz 2MB L2 cache 8GB DDR3 SO DIMM 3 10 100 1000 BaseT...

Page 5: ...ncluding compliance and rating information Preinstalled Windows 10 IoT Enterprise 64 bit license Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the...

Page 6: ... is USB 2 0 compliant and is compatible with USB 1 1 and 1 0 devices SeaLatch USB Type A to USB Type B 5 Meter Length Device Cable Item CA355 5M The CA355 5M is a 5 meter 16 feet USB device cable with Sealevel s SeaLatch locking USB type A connector and standard type B connector The metal thumbscrew on the type A connector provides a secure metal to metal connection to devices with SeaLatch USB po...

Page 7: ...B 72 Length Device Cable Item CA356 The CA356 is a 72 USB device cable that securely connects USB device port metal thumbscrew lock to a host computer The CA356 is USB 2 0 compliant and is compatible with USB 1 1 and 1 0 devices CAT5 Patch Cable 7 in Length Blue Item CA246 Standard 7 CAT5 UTP Patch Cable RJ45 Power Supply 100 240VAC to 12VDC 4 0A LPS Desktop Power Supply Item TR135 The TR135 is a ...

Page 8: ... with 8GB DDR3L SDRAM operational memory and is also designed to support a SATA CFAST Type I II memory card for bulk storage Ethernet The HazPAC10 8 4 includes 3 Gigabit Ethernet ports Pin Signal GbE Signal 1 TX BI_DA 2 TX BI_DA 3 RX BI_DB 4 C BI_DC 5 C BI_DC 6 RX BI_DB 7 D BI_DD 8 D BI_DD 3 Gigabit Ethernet Ports ...

Page 9: ...INUED USB The HazPAC 10 8 4 provides 4 SeaLATCH USB 2 0 ports Connector Rugged USB 2 0 Type A vertical right angle receptacle Manufacturer Samtec Description Rugged USB Type A Exceeds retention force of 15N Mates with SeaLATCH USB Type A or Standard USB Type A 4 SeaLATCH USB 2 0 Ports ...

Page 10: ...een with glass top The 5 wire resistive touchscreen is rated for 200 million presses touches The touchscreen is calibrated at the factory If recalibration is necessary please use the calibration tool included with existing PenMount driver Below are images of the screen from a frontal view and the display screen face down With the display face down you can see all external input and output ports Di...

Page 11: ...t with there are two isolated RS 485 serial ports which are provided via a 6 position 3 5mm pitch terminal block with screw retention The RS 485 serial port has adjacent DIP switches to Pull up Pull Down the data lines and to add Termination across each data pair Finally two RS 232 serial ports with full modem control are provided which interface via DB9 male connectors ...

Page 12: ...L9363 5 2022 TECHNICAL DESCRIPTION CONTINUED Connectors RS 485 port 1 and RS 485 port 2 Description 6 Position 3 5mm Terminal Block PIN RS 485 Isolated 1 ISOGND1 2 DATA1 3 DATA1 4 ISOGND2 5 DATA2 6 DATA2 1 2 3 4 5 6 RS 485 Port 1 and RS 485 Port 2 ...

Page 13: ...H1400811 8 4 Manual SL9363 5 2022 TECHNICAL DESCRIPTION CONTINUED Connectors RS 232 port 1 and RS 232 port 2 Description DB 9 Male PIN RS 232 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI RS 232 Port 1 and RS 232 Port 2 ...

Page 14: ...Power Supply Limited Power Source or LPS suitable for the maximum ambient temperature at the installation 9 30VDC Input Power The voltage applied here is also present on the Open Collector output VIN pin and can be used to power the open collector outputs Absolute Operating Range 9 30VDC Rated Voltage 12 27VDC 3A 1 1A respectively Power Usage 15W nominal 30W max ...

Page 15: ...NABLED Terminate between D and D lines with 120 ohm resistor PU OFF Down or away from screen ON Up or toward screen DISABLED No pull up ENABLED Pull up D line to isolated 3 3V ISO1 plane via 510 ohm resistor PD OFF Down or away from screen ON Up or toward screen DISABLED No pull down ENABLED Pull down D line to isolated GND ISO1 plane via 510 ohm resistor The pull up and pull down resistors ensure...

Page 16: ... can be combined to increase the sink current in 100mA increments Connector OPEN COLLECTOR Manufacturer MOLEX Part Number 39506 1006 Description 6 Position Right Angle 3 5mm Header Mates with MOLEX 39504 0006 6 Position 3 5mm Pluggable Screw Terminal Screw Torque 5 5 in lbs 0 62 Nm Wire gauge AWG 16 30 1 31mm2 0 05mm2 Wire rating 85 C or higher Pin Signal 1 GND 2 Output 1 3 Output 2 4 Output 3 5 O...

Page 17: ...ernal power supply is protected by internal resettable 0 5A fuse and the outputs are protected by integrated flyback diodes External Voltage Wiring with Internal Flyback Protection Under some scenarios you can utilize the internal flyback diodes when using an external power source This scenario is only possible if your external power source is a higher voltage than the power supply of the HazPAC 1...

Page 18: ...tion Voltage can be provided independently HazPAC 10 s power supply if Vin is not connected However this also removes the integrated flyback protection You will need to add your own flyback diodes if you are switching inductive loads External flyback diodes are required to protect the outputs when switching inductive loads ...

Page 19: ...eplaced To do this remove all screws from the cover for the memory card port The existing card can then be pulled from the port and a new card inserted Reinstall the port cover before connecting power to the device The existing card can then be pulled from the port and a new card inserted Reinstall the port cover before connecting power to the device SATA CFast Type I II Memory Card Port ...

Page 20: ...Processor and peripherals will be issued a reset command when the Reset button is pressed and held for 5 6 seconds Use a blunt non conductive instrument to depress the reset button Power Button on the Left and Reset Button on the Right Just like with the Reset button the Power button needs to be pressed and held for 5 6 seconds to turn the device on or off ...

Page 21: ... 2 Software SeaCOM Windows Sealevel 3 PenMount Windows Universal Driver for touch screen A Please select PenMount 6000 6010 USB from the Controller dropdown menu The below links require a free Congatec account 4 Congatec Conga TCA3 5 Congatec Intel HD Graphics Driver 6 Congatec Trusted Execution Engine 7 Congatec Intel Chipset SeaMAX Application Suite SeaMAX Overview Sealevel digital and analog I ...

Page 22: ...X MaxSSD it will default to the Connection tab This tab allows the user to choose the initial communication settings for the connected I O device To communicate with the Digital Outputs of the HazPAC 10 select SeaDAC Lite USB from the Type dropdown box MAXSSD will search for the internal SeaDAC Lite You should see the internal SeaDAC Lite displayed on the right hand frame as model number 9194 Doub...

Page 23: ...ed device Each Digital Output can be activated or deactivated using the buttons below each output LED The corresponding status LED in the Digital IO window indicates the state of the outputs A green LED above the digital output indicates the Digital Output is active a darkened LED indicates it is inactive The example below shows the 4 Digital Outputs of the HazPAC 10 in an inactive state The SeaIO...

Page 24: ...Outputs verify SeaMAX Software Suite is fully installed 3 Confirm that all screw terminal connections are correct and secure Use the MaxSSD utility to verify proper installation 4 MaxSSD is designed to simplify the installation configuration and diagnostics of Digital Outputs of the HazPAC 10 If these steps do not solve your problem please call Sealevel Systems Technical Support 864 843 4343 Our t...

Page 25: ...oblem This will eliminate any software issues from the equation Troubleshooting Verification for Asynchronous Serial Products The HazPAC 10 has two 2 wire RS 485 serial ports meaning the transmitter and receiver to the same data channel For this reason an external loopback adapter will not work with 2 wire RS 485 To successfully perform a loop back test with 2 wire RS 485 the easiest method is to ...

Page 26: ...n button RS485 only Launch a second WinSSD window and select the COM port of the other RS485 port 5 This will first open the COM port From this tab the port can also be closed See image below Click the Settings button to open the COM Port Properties dialog box This willallow the Port Settings to be altered 6 Change your parameters to 9600 bits per second 8 data bits no parity 1 stop bit and no flo...

Page 27: ...ick Apply and OK 8 In the main WinSSD window click on the BERT tab Bit Error Rate test 9 RS232 Click on the Start button RS485 Only click Start on one instance of WinSSD Since the RS485 ports are half duplex we cannot run the BERT test simultaneously on both ports ...

Page 28: ...ames will increase The Tx and Rx Data Rates will show the calculated data rate Passing RS232 loopback test RS 485 If the COM port is properly working the Sync Status green light will glow on the receive port Transmit Frames will increase on the port running the BERT test Receive Frames will increase on the receive port The Tx and Rx Data Rates will show the calculated data rate ...

Page 29: ... Sealevel Systems Inc H1400811 8 4 Manual SL9363 5 2022 Passing RS485 loopback test WinSSD in top image is transmitting port 11 RS485 only Click on the Stop button Repeat steps 11 and 12 on the other port ...

Page 30: ...363 5 2022 Passing RS485 loopback test WinSSD in bottom image is transmitting port 12 This verifies that the adapter is working properly You can continue testing this port withdifferent configurations or proceed with testing other ports if necessary ...

Page 31: ...ovides an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a web page on the Internet Our home page address is www sealevel com The latest software updates and newest manuals are available via our web site Technical support is available Monday to Friday from 8 00 AM to 5 00 PM East...

Page 32: ...32 Sealevel Systems Inc H1400811 8 4 Manual SL9363 5 2022 Appendix C CAD Drawing 8 4 model ...

Page 33: ...pean Commission Electromagnetic Compatibility Directive 2014 30 EU Low Voltage Directive 2014 35 EU ATEX Directive 2014 34 EU RoHS Directive 2011 65 EU EU 2015 863 China Compulsory Certification Statement The product s is verified and certified according to CNCA C23 01 2019 China Compulsory Certification Implementation Rule on Explosion Protected Electrical Product and CNEX C2301 2019 Guideline of...

Page 34: ...cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is provided or if an alternate cable is required use high quality shielded cabling to maintain compliance with FCC EMC directives ...

Page 35: ...arranty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable This warranty applies to Sealevel man...

Reviews: