© Sealevel Systems, Inc.  2104 Manual   |  SL9092  9/2021 

Appendix A 

 Troubleshooting 

Serial  Utility  test  software  is  supplied  with  the  Sealevel  Systems  adapter  and  will  be  used  in  the 
troubleshooting  procedures.  Using  this  software  and  following  these  simple  steps,  most  common 
problems can be eliminated without the need to call Technical Support. 

1.

 

If your adapter isn’t working, first check to make sure that USB support is enabled in 

the System BIOS and it is functioning properly in the operating system. This can be 
done by using either the Windows 98/ME or Windows 2000 Device Manager. 

2.

 

Ensure that the Sealevel Systems software has been installed on the machine so that 
the necessary files are in place to complete the installation.  

3.

 

When the 

485I

 is configured properly, the USB Enabled LED (EN) will be lit. 

This should allow you to use S

ealevel’s WinSSD utility and the supplied loopback plug 

to  check  communications.  The  supplied  loopback  plug  connects  TD  to  RD.    If  you 
decide to test the Modem  Control Signals, a full pin loopback plug will be required.  
Details on loopback plugs are included within WinSSD.  Contact Sealevel Systems if 
you need further assistance.   

4.

 

When testing the 

485I

 in loopback mode, you should see both the TD and RD 

LED’s flashing as well as seeing echoed data on the screen. The loopback test first 

transmits a HEX pattern, 55AA, and then an ASCII string of data. If this test passes, 
then the 

485I

 is ready for use in your application. 

5.

 

Please note that if the card is configured for 2 wire RS-485 with no echo a loopback 
test is not possible. The receiver in this case will be turned off and the test will fail. If 
you plan on using this device in two wire mode test the adapter in RS-422 mode first. 
Then configure the adapter for your application.  

 

 

 

 

 

 

 

 

Summary of Contents for SEALINK+485I

Page 1: ...1 Sealevel Systems Inc 2104 Manual SL9092 9 2021 SEALINK 485I User Manual 2104...

Page 2: ...ARE INSTALLATION 6 CONFIGURATION 8 TECHNICAL DESCRIPTION 10 SPECIFICATIONS 11 APPENDIX A TROUBLESHOOTING 12 APPENDIX B HOW TO GET ASSISTANCE 13 APPENDIX C ELECTRICAL INTERFACE 14 APPENDIX D GROUND LOO...

Page 3: ...422 485 Asynchronous serial port providing a versatile interface for common RS 422 485 needs The SeaLINK 485I connects through the PC s external USB port so it does not require opening the computer c...

Page 4: ...g to Upstream Host Hub Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Importan...

Page 5: ...Operating Systems Refer to the appropriate section of the Serial Utilities Software For additional software support please call Sealevel Systems Technical Support 864 843 4343 Our technical support is...

Page 6: ...switch for your specific application Please see the Configuration section for more information The SeaLINK 485I is defaulted to RS 422 mode so changes are only required if you will be using the produ...

Page 7: ...port by using the assigned COM identifier shown above In this case it is COM5 but this assignment will vary from system to system At this point the hardware is recognized To verify operation use Seal...

Page 8: ...position either enables adds or connects based on the function of the switch position listed below Switch SW1 position OFF disables removes or disconnects SW1 Function 1 RS 485 Two Wire Auto Enable Di...

Page 9: ...gure 2 is the first RS 485 picture 1 ON 2 off 3 ON 4 ON 5 ON 6 ON 7 ON 8 off Figure 3 is the second RS 485 picture 1 ON 2 ON 3 ON 4 ON 5 ON 6 ON 7 ON 8 off ON 1 2 3 4 5 6 7 8 OFF RS 422 Figure 1 RS 42...

Page 10: ...opening the case No system resources are required i e I O ports or IRQ s LED status indicators for USB Enabled TD and RD Connector Pin Assignments DB25 Male The SeaLINK 485I complies with the EIA 530...

Page 11: ...ing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask o...

Page 12: ...ED EN will be lit This should allow you to use Sealevel s WinSSD utility and the supplied loopback plug to check communications The supplied loopback plug connects TD to RD If you decide to test the M...

Page 13: ...an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a web page on the Internet Our...

Page 14: ...or RS 485 RS 485 is backwardly compatible with RS 422 however it is optimized for party line or multi drop applications The output of the RS 422 485 driver is capable of being Active enabled or Tri St...

Page 15: ...t can cause equipment malfunction or even destruction Cabling Recommendations When connecting the SeaLINK 485I in an RS 485 network care should be taken that both ends of the network are not isolated...

Page 16: ...of the character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Asynchronous Commu...

Page 17: ...17 Sealevel Systems Inc 2104 Manual SL9092 9 2021 Appendix F Silk Screen 3 28 in 2 09in 1 39in...

Page 18: ...to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23...

Page 19: ...ty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepa...

Reviews: