Configuration 

Electrical Interface Selection 

The port on the 

485I 

has the ability to be used in both half and full duplex RS-422/485 applications. 

This is selectable through DIP-

switch SW1. The chart below describes each of the switch position’s function. 

Please refer to the following page for switch setting examples. Switch SW1, in the “ON” position, either 

enables, adds, or connects, based on the function of the switch position listed below. Switch SW1, position 
OFF, disables, removes, or disconnects . 

SW1

 

Function

 

1

 

RS-485  Two Wire Auto Enable/Disable

 

2

 

Echo Enable/Disable

 

3

 

Adds or removes the 120-ohm termination

 

4

 

Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485 receiver circuit 

(Receive data only)

 

5

 

Adds or removes the 1K ohm pull-down resistor in the RS-422/RS-485 receiver 

circuit (Receive data only)

 

6

 

Connects the TX+ to RX+ for RS-485 two wire operation

 

7

 

Connects the TX- to RX- for RS-485 two wire operation

 

8

 

Not Used

 

 

 

 

Summary of Contents for SEALINK+485I

Page 1: ...1 Sealevel Systems Inc 2104 Manual SL9092 9 2021 SEALINK 485I User Manual 2104...

Page 2: ...ARE INSTALLATION 6 CONFIGURATION 8 TECHNICAL DESCRIPTION 10 SPECIFICATIONS 11 APPENDIX A TROUBLESHOOTING 12 APPENDIX B HOW TO GET ASSISTANCE 13 APPENDIX C ELECTRICAL INTERFACE 14 APPENDIX D GROUND LOO...

Page 3: ...422 485 Asynchronous serial port providing a versatile interface for common RS 422 485 needs The SeaLINK 485I connects through the PC s external USB port so it does not require opening the computer c...

Page 4: ...g to Upstream Host Hub Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Importan...

Page 5: ...Operating Systems Refer to the appropriate section of the Serial Utilities Software For additional software support please call Sealevel Systems Technical Support 864 843 4343 Our technical support is...

Page 6: ...switch for your specific application Please see the Configuration section for more information The SeaLINK 485I is defaulted to RS 422 mode so changes are only required if you will be using the produ...

Page 7: ...port by using the assigned COM identifier shown above In this case it is COM5 but this assignment will vary from system to system At this point the hardware is recognized To verify operation use Seal...

Page 8: ...position either enables adds or connects based on the function of the switch position listed below Switch SW1 position OFF disables removes or disconnects SW1 Function 1 RS 485 Two Wire Auto Enable Di...

Page 9: ...gure 2 is the first RS 485 picture 1 ON 2 off 3 ON 4 ON 5 ON 6 ON 7 ON 8 off Figure 3 is the second RS 485 picture 1 ON 2 ON 3 ON 4 ON 5 ON 6 ON 7 ON 8 off ON 1 2 3 4 5 6 7 8 OFF RS 422 Figure 1 RS 42...

Page 10: ...opening the case No system resources are required i e I O ports or IRQ s LED status indicators for USB Enabled TD and RD Connector Pin Assignments DB25 Male The SeaLINK 485I complies with the EIA 530...

Page 11: ...ing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask o...

Page 12: ...ED EN will be lit This should allow you to use Sealevel s WinSSD utility and the supplied loopback plug to check communications The supplied loopback plug connects TD to RD If you decide to test the M...

Page 13: ...an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a web page on the Internet Our...

Page 14: ...or RS 485 RS 485 is backwardly compatible with RS 422 however it is optimized for party line or multi drop applications The output of the RS 422 485 driver is capable of being Active enabled or Tri St...

Page 15: ...t can cause equipment malfunction or even destruction Cabling Recommendations When connecting the SeaLINK 485I in an RS 485 network care should be taken that both ends of the network are not isolated...

Page 16: ...of the character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Asynchronous Commu...

Page 17: ...17 Sealevel Systems Inc 2104 Manual SL9092 9 2021 Appendix F Silk Screen 3 28 in 2 09in 1 39in...

Page 18: ...to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23...

Page 19: ...ty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepa...

Reviews: