background image

INSTRUCTIONS FOR

ARC WELDERS

150XL.V3
150XTC.V3 
160XTC.V3
200XTC.V3

Models:

Arc Welders 150XL.V3,150XTC.V3,160XTC.V3,200XTC.V3  - 1 - 200707

Summary of Contents for 150XL.V3

Page 1: ...INSTRUCTIONS FOR ARC WELDERS 150XL V3 150XTC V3 160XTC V3 200XTC V3 Models Arc Welders 150XL V3 150XTC V3 160XTC V3 200XTC V3 1 200707 ...

Page 2: ... important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity at Work Act 1989 requires that all portable electrica...

Page 3: ...5 160A Ø2 4mm Turbo Fan 16mm2 49V 230V 1ph 21 kg 5 98 kVA 200XTC V3 55 200A Ø2 4mm Turbo Fan 16mm2 52V 230V 1ph 27 kg 5 98 kVA HEAVY DUTY TURBO COOLED ARC WELDERS Turbo Forced Air Cooling System the XTC range has increased duty cycle and performance Featuring single vented wrap around shells fitted to a heavy duty chassis with wheels and chassis support and a screw type stepless welding current co...

Page 4: ...u identify your model s control panel symbols ELECTRO FAN Cools the machine when running THERMOSTATIC PROTECTION Lights up when the machine overheats and cuts out The machine can be used again when cooled SWITCH POSITION settings EARTH CLAMP REGULATION SCALE RAIN WARNING SYMBOL DO NOT use the machine in the rain or snow ELECTRODE HOLDERS Various The electrode holder is connected to the machine via...

Page 5: ...wer supply See fig 4 1 5 4 3 Attach the earth clamp to a point on the workpiece that has been cleanly ground to provide good contact Attach it as close as possible to the joint to be made 5 4 4 For welders supplied with terminals the earth lead must be connected to the terminal associated with the following symbol 5 4 1 Select the diameter of electrode to be used in relation to the type of joint t...

Page 6: ...pply Consideration should also be given to shielding the supply cable of permanently installed equipment in metallic conduit or equivalent This shielding should be connected to the power source so that good electrical contact is maintained between the conduit and the welding power source enclosure 8 6 Maintenance of the equipment The equipment should be routinely maintained according to these inst...

Page 7: ......

Page 8: ...ey co uk 01284 703534 e mail Web www sealey co uk ARC W WELDERS MODELS 150XL V3 150XTC V3 160XTC V3 200XTC V3 ARC WELDERS Models 150XL V3 150XTC V3 160XTC V3 200XTC V3 73 23 EEC Low Voltage Directive 89 336 EEC EMC Directive 93 68 EEC Marking Directive BS EN 60974 6 We the sole importer into the UK declare that the products listed below are in conformity with the following standards and directives...