background image

5.8. 

  

If the operating note of the compressor changes, there may be a blockage within the air brush or the air hose may be pinched. The unit  

 

should be switched off immediately and the source of the blockage investigated and eliminated.

5.9. 

  

When the task is complete use the compressor to blow a suitable cleaning solvent through your air brush.

5.10. 

Switch the unit off. operate the air brush to relieve any pressure left in the hose. disconnect the air brush from the compressor.

5.11. 

drain off any moisture by lifting the drain valve.

5.12. 

during and immediately after operation, the finned pump head may be hot and should not be touched. If the unit must be moved, lift it by  

 

the handle only. Allow the unit to cool before storing it. 

5.13. 

Should there appear to be any loss of efficiency when spraying, ensure first that the air brush is scrupulously clean and functioning    

 properly. 

6.  mAinTEnAnCE

 

‰

   WARninG! Before carrying out any maintenance, switch compressor off, unplug it from the mains electricity supply, 

 

de-pressurise the tank and allow unit to fully cool down.

 

6.1. 

  

Keep the unit clean at all times. 

6.2. 

  

DO nOT

 cover any of the ventilation slots. 

DO nOT

 allow any extraneous material to enter the unit via any of the ventilation openings. 

6.3. 

  

Store in dust free and dry conditions.

.

Original Language Version

© Jack Sealey limited

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7AR

 01284 757500 

 01284 703534 

 sales@sealey.co.uk 

 www.sealey.co.uk

EnViROnmEnT PROTECTiOn

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

WEEE REGULATiOnS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

A

B900.V4 | Issue:1     23/09/19

note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on technical@sealey.co.uk or 01284 757505.

important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.