WARNING!

 

Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this  

 

 equipment.

  Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

  Maintain the pump station in good condition (use an authorised service agent).

  Replace or repair damaged parts. 

Use genuine parts only. Non authorised parts will invalidate the warranty.

  Use only to dispense water and urea solutions.

  Ensure safety eye protection and protective clothing are worn when using this product.

  Keep the work area clean, uncluttered and ensure there is adequate lighting.

  Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

  Keep children and unauthorised persons away from the working area.

  After use, drain any fluids from the equipment before storage. 

  Dispose of waste liquids in accordance with local authority regulations.

 

DO NOT 

exceed the maximum pressure of 50psi.

 

DO NOT 

point the nozzle at people or animals.

 

DO NOT 

use the equipment near open flames.

 

DO NOT 

smoke whilst using this equipment. 

 

DO NOT 

use to extract corrosive fluids.

 

DO NOT

 dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.

 

DO NOT

 use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

  Keep the pump clean and store in a safe dry, childproof location. 

  

WARNING! DO NOT

 allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to 

  local authority regulations.

InstRUctIons FoR:

PROFESSIONAL ADbLuE®

AuTOMATIC DE

LIVERY NOZZLE

WITH METER

MoDEl no: 

ADb06

  1.  SAFETY INSTRuCTIONS

 2.  INTRODuCTION

 3.  INSTALLATION

IMPORTANT:

 

PLEASE READ THESE INSTRuCTIONS CAREFuLLY. NOTE THE SAFE OPERATIONAL REQuIREMENTS, 

WARNINGS AND CAuTIONS. uSE THIS PRODuCT CORRECTLY AND WITH CARE FOR THE PuRPOSE FOR WHICH IT IS 

INTENDED. FAILuRE TO DO SO MAY CAuSE DAMAGE OR PERSONAL INJuRY AND WILL INVALIDATE THE WARRANTY.  

PLEASE RETAIN THESE INSTRuCTIONS FOR FuTuRE uSE.

thank you for purchasing a sealey product. Manufactured to a high standard this product will give you years of trouble free performance

if these instructions are carefully followed and the product is correctly maintained.

ADB06

Issue no: 1 - 19/06/13

lightweight yet durable nozzle developed to meet the International standards of urea dispensing. this AdBlue® nozzle has an incorporated 

ADB02 digital flow meter, which allows the user to view the delivery readings at the vehicle. Manufactured using AdBlue® compliant materials 

and fitted with 3/4"BSP hose inlet. Features a maximum flow rate of 35ltr/min.

  4.  NOZZLE OPERATION

 

Ensure the pump is turned off.

3.1

  Apply a sealant (e.g: PTFE tape) thinly to hose thread 

3.2

  screw the hose into the new nozzle and tighten by using  

 

a wrench on the hose nut only, (do not overtighten).

3.3

  the nozzle is now ready for use.

4.1

  Place the nozzle fully into the receiving tank.

4.2

  Squeeze trigger (fig.1) to dispense fluid.

4.3

  The trigger may be locked in the open position by squeezing and pushing the trigger lock back. (fig.2). This feature can be disabled if  

 

necessary by removing the 'U' shaped staple from the handle. (Drift the staple out with a small pin-punch).

4.4

  When the level of the fluid reaches the tip of the nozzle the flow will close off automatically.

4.5

  When not in use, place the nozzle in a leak proof housing. 

fig.1

fig.2

    Original Language Version 

© Jack sealey limited

ADb06

Measurement system

Turbine (Polypropylene)

Flow Rate

35 ltr/min

operating pressure (Max) 50psi
storage temperature 

(Range)

-20°c to 70°c

storage humidity (Max)

95%

operating temperature 

(Range)

-10°c to 50°c

Viscosity (Range)

2 to 5.35 cst

Accuracy 

(between 15 and 120l/min)

+/-1% of value indicated 

after calibration

Reproducibility (typical)

+/- 0.3%

Power supply

2 x 1.5V AAA alkaline batteries (included)

Battery life

18 to 36 months

compatible Fluids

Water, Urea

Inlet connection:

¾

" BSP

Summary of Contents for Adblue ADB06

Page 1: ...ORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the product is cor...

Page 2: ...3 Indication of calibration mode 4 Totals register 6 figures with moving comma FROM 0 1 to 999999 that can indicate two types of Total 4 1 General Total that cannot be reset TOTAL 4 2 Resettable total Reset TOTAL 5 Indication of total multiplication factor x10 x100 6 Indication of type of total TOTAL Reset TOTAL 7 Indication of unit of measurement of Totals L Litres Gal Gallons 8 Indication of Flo...

Page 3: ...nd hold down the CAL button Why enter the calibration phases To display the currently used calibration factor Return to factory k factor after a previous calibration with user k factor Change the calibration factor using one of the two previously indicated procedures In calibration mode the partial and total dispensed quantities indicated on the display screen take on different meanings according ...

Page 4: ...Real value ADB02 calculates the new USER K FACTOR This calculation could require a few seconds depending on the correction to be made During this operation the arrow disappears but the CAL indication remains If this operation is performed after operation 5 4 5 without changing the indicated value the USER K FACTOR would be the same as the FACTORY K FACTOR thus it is ignored 6 4 9 At the end of the...

Page 5: ...ogether with the unit of measurement set at that time in this example Litres Litres 6 6 3 Press the RESET key to select the desired combination of unit of measurement amongst those shown below 6 6 4 Save the new combination by pressing the CAL key at length ADB02 will pass through the start cycle and will then be ready to dispense in the set units q WARNING The Resettable Total and Total registers...

Page 6: ...gue on 01284 757525 and leave your full name and address including your postcode Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s Batteries Producer Registration Number BPRN ...

Reviews: