7. TROubLESHOOTING

Problem

Possible Cause

Remedy

no lcD display

Bad battery connection

check /clean Battery terminals

Batteries expired

Replace batteries

Incorrect measurements

Wrong K Factor

Refer to section 5 calibration

Flow rate below meter limits

Increase flow rate

Reduced or zero flow rate

turbine blocked

contact your sealey dealer

Meter not recording flow

Faulty PCB

contact your sealey dealer

Faulty turbine

contact your sealey dealer

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

no liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for

 any claim. 

INFORMATION: 

Call us for a copy of our latest catalogue on 01284 757525 and leave your full name and address including your postcode.

Under the Waste Batteries and Accumulators Regulations 2009, Jack sealey ltd are required to inform potential purchasers of products 

containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. 

Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705.  See section 7.1 for battery removal details

Environmental Protection.

Recycle unwanted materials instead of disposing of them as 

waste. All tools, accessories and packaging should be sorted, 

taken to a recycle centre and disposed of in a manner which  

is compatible with the environment.

WEEE Regulations.

Dispose of this product at the end of its working life in compliance   

with the EU Directive on Waste Electrical and Electronic Equipment.  

When the product is no longer required, it must be disposed of in an 

environmentally protective way. contact your local solid waste  

authority for recycling information.

Summary of Contents for Adblue ADB06

Page 1: ...ORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the product is cor...

Page 2: ...3 Indication of calibration mode 4 Totals register 6 figures with moving comma FROM 0 1 to 999999 that can indicate two types of Total 4 1 General Total that cannot be reset TOTAL 4 2 Resettable total Reset TOTAL 5 Indication of total multiplication factor x10 x100 6 Indication of type of total TOTAL Reset TOTAL 7 Indication of unit of measurement of Totals L Litres Gal Gallons 8 Indication of Flo...

Page 3: ...nd hold down the CAL button Why enter the calibration phases To display the currently used calibration factor Return to factory k factor after a previous calibration with user k factor Change the calibration factor using one of the two previously indicated procedures In calibration mode the partial and total dispensed quantities indicated on the display screen take on different meanings according ...

Page 4: ...Real value ADB02 calculates the new USER K FACTOR This calculation could require a few seconds depending on the correction to be made During this operation the arrow disappears but the CAL indication remains If this operation is performed after operation 5 4 5 without changing the indicated value the USER K FACTOR would be the same as the FACTORY K FACTOR thus it is ignored 6 4 9 At the end of the...

Page 5: ...ogether with the unit of measurement set at that time in this example Litres Litres 6 6 3 Press the RESET key to select the desired combination of unit of measurement amongst those shown below 6 6 4 Save the new combination by pressing the CAL key at length ADB02 will pass through the start cycle and will then be ready to dispense in the set units q WARNING The Resettable Total and Total registers...

Page 6: ...gue on 01284 757525 and leave your full name and address including your postcode Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s Batteries Producer Registration Number BPRN ...