background image

❐ 

WARNING!

 

Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this  

 

  equipment.

  Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

  Maintain the pump station in good condition (use an authorised service agent).

  Replace or repair damaged parts. 

Use genuine parts only. Non authorised parts will invalidate the warranty.

  Use only to pump lubricants up to SAE 150 viscosity, used oil and antifreeze liquids. 

  Ensure safety eye protection, oil resistant gloves and protective clothing are worn when using this product.

  Keep the work area clean, uncluttered and ensure there is adequate lighting.

  Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

  Keep children and unauthorised persons away from the working area.

  After use, drain any fluids from the equipment before storage. 

  Dispose of waste liquids in accordance with local authority regulations.

  Disconnect air pressure from equipment when not in use.

 

DO NOT 

exceed the maximum air pressure of 115psi.

 

DO NOT 

point the nozzle at people or animals.

 

DO NOT 

use the equipment near open flames.

 

DO NOT 

smoke whilst using this equipment.

 

DO NOT 

use to extract corrosive fluids.

 

DO NOT

 dismantle, tamper with or adapt the pump for any purpose other than for which it is designed.

 

DO NOT

 use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

 

DO NOT 

leave the trolley on a slope, or traverse slopes, which may cause the unit to topple. 

  The unit must be stored on a level surface.

  Keep the pump clean and store in a safe dry, childproof location. 

❐  

WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to 

  local authority regulations.

InSTRUcTIonS FoR:

OIl DIspeNsING 

sysTem AIR OpeRATeD 

Model no: 

AK4561D

  1.  sAFeTy INsTRUCTIONs

  2.  INTRODUCTION

IMPORTANT:

 

pleAse  ReAD  THese  INsTRUCTIONs  CAReFUlly.  NOTe  THe  sAFe  OpeRATIONAl  ReQUIRemeNTs, 

WARNINGs AND CAUTIONs. Use THIs pRODUCT CORReCTly AND WITH CARe FOR THe pURpOse FOR WHICH IT Is 

INTeNDeD. FAIlURe TO DO sO mAy CAUse DAmAGe OR peRsONAl INJURy AND WIll INVAlIDATe THe WARRANTy.  

pleAse ReTAIN THese INsTRUCTIONs FOR FUTURe Use.

Thank  you  for  purchasing  a  Sealey  product.  Manufactured  to  a  high  standard  this  product  will  give  you  years  of  trouble  free  performance

if these instructions are carefully followed and the product is correctly maintained.

AK4561D

Issue no: 1 - 14/11/08

Mobile oil dispensing unit with air operated 3:1 double acting pump for barrel or 

tanks with 2”BSP fittings. Pump is supplied with air management system and 

connected to a 940mm rigid suction probe with non-return valve. Features 4mtr 

hose and digital oil meter Model no. AK4565D. Suitable for use with engine, 

hydraulic, synthetic, gear and transmission oils up to SAE150.

Air operated Pump
Model:

AK4561D

Pump Ratio:

3:1

Maximum Flow Rate:

12ltr/min

Maximum Viscosity:

150SAE

Maximum output Pressure:

350psi

Maximum Air Pressure:

115psi

Recommended Air Pressure:

70psi

outlet:

1/2”BSP

Trolley Maximum capacity:

220kg

Digital Hose End Meter
Model:

AK4565D

Accuracy:

+/- 0.5%

Inlet:

1/2”BSP

Battery:

Lithium cR2 3V 1400mAH

Summary of Contents for AK4561D

Page 1: ... a slope or traverse slopes which may cause the unit to topple The unit must be stored on a level surface Keep the pump clean and store in a safe dry childproof location WARNING DO NOT allow uncontrolled discharge of fluids thus polluting the environment All liquids must be disposed of according to local authority regulations Instructions for Oil dispensing system air operated Model No AK4561D 1 S...

Page 2: ... secure using knob 1 3 1 7 Adjust the pump support brackets so that they fully support the pump assembly and check all nuts are tight 3 2 Pump and Air Regulator Lubricator Assembly 3 2 1 Apply a small amount of liquid thread sealant onto the threads of the air inlet of the pump and attach the air regulator lubricator fig 2 WARNING DO NOT allow thread sealant to enter the pump 3 2 2 Attach the outl...

Page 3: ...g 5 1 and fig 5 2 simultaneously to display the current correction factor Qty Dispensed Qty Indicated x Current Correction Factor New Correction Factor 4 6 Programming the Correction Factor 4 6 1 Remove the rubber protective cover from the meter and unscrew the four phillips screws fig 6 holding the digital meter remove from the gun 4 6 2 Press button 2 on the rear of the meter fig 7 2 for 1 sec t...

Page 4: ...pensing System Air Operated Model AK4561D 2002 95 EC RoHS Directive 2002 96 EEC WEEE Directive 14th November 2008 Signed by Steve Buckle AK4561D Issue No 1 14 11 08 fig 9 5 1 Changing the Digital Meter Battery 5 1 1 Remove the rubber protective cover from the meter 5 1 2 Remove the screw and cover from the side of the meter 5 1 3 Remove and replace battery fig 8 5 1 4 Replace cover and secure with...

Reviews: